LS 3603-I265A Special Operating Instructions
(73-13583-265)
Revision B: June 2000
4
used to identify value of param-
eter.
Host Commands
Table 1: Host Commands
Value
Hex
Rep.
Command
Scanner
Response
0
30h
Change Single
Parameter
If valid, the specified
parameter is changed
to the downloaded
value and an ACK
String is sent to the
host.
1
31h
Change a Group
of Parameters
If valid, all the
parameters within the
specified group (set
code types, set scan
formatting bits, etc.)
are set and an ACK
String is sent to the
host. For more infor-
mation on groups see
Param Group section.
2
32h
Change All
Parameters
All the scanner's
parameters are set to
the specified values
and an ACK String is
sent to the host.
3
33h
Reset Defaults
The scanner resets
defaults and sends an
ACK String to the
host.
4
34h
Upload All
Parameters
The scanner's cur-
rent parameter con-
figuration is sent to
the host.
5
35h
Software Identi-
fication Request
The scanner’s soft-
ware identification
string is sent to the
host.
6
36h
Control Scan-
ner’s Green LED
An ACK string is sent
to the host and the
scanner turns the
Green LED ON or
OFF as per the com-
mand.