LS 3603-I265A Special Operating Instructions
(73-13583-265)
Revision B: June 2000
25
Change two single
params
Full Length = 22 (22
= 16h, = 30h, 31h,
36h)
Autod UPC supps:
Length = 005;
Host Command = 0;
Param Group = 1;
Param ID = 0E;
Param Value = 2h;
Conv UPCE to
UPCA:
Length = 005;
Host Command = 0;
Param Group = 2;
Param ID = 00;
Param Value = 1h
Valid
:
02h,30h,31h,36h,
30h,30h,35h,30h,
31h,30h,45h,02h,
30h,30h,35h,30h,
32h,30h,30h,01h,
03h,LRC;
Invalid
:
02h,30h,31h,36h,
30h,30h,35h,30h,
31h,30h,45h,02h,
30h,30h,34h,30h,
32h,30h,30h,01h,
03h,LRC (34h,
invalid length for
second command)
ACK String
:
<Length=009>
<Command=00>
02h,30h,30h,39h,
06h,30h,30h,03h,
LRC
NAK String
:
<Length =011 =
0Bh> <Reason = A
= 41h > <Error
Location =015 =
0Fh>02h,30h,30h,
42h,15h,41h,30h,
30h,46h,03h, LRC
Note
: First host
command is exe-
cuted, UPC Supple-
mentals changed to
autodiscriminate
Change a Group of
Params
Full Length = 18 (18
= 12h, = 30h, 31h,
32h);
Serial Bit Params:
Length = 009;
Host Command = 1;
Param Group = 6;
Param ID = 0h,0h;
Param Values:
Reserved = 0h; Check
Parity = 1h; Reserved
= 0h; Reserved = 0h;
Host RTS State = 0h
Valid
:
02h,30h,31h,32h,
30h,30h,39h,31h,
36h,00h,00h,00h,
01h,00h,00h,00h,
03h,LRC
Invalid
:
02h,30h,31h,32h,
30h,30h,39h,31h,
3Ah,0h,00h,00h,
01h,00h,00h,00h,
03h,LRC (3Ah,
invalid group)
ACK String
:
<Length=008>
<Command=1>
02h,30h,30h,38h,
06h,31h,03h,LRC
NAK String
:
<Length
=011=0Bh><Rea-
son = C = 43h >
<Error Location
=009>
02h,30h,30h,42h,
15h,43h,30h,30h,
39h,03h, LRC
Table 13: Data Transmission Examples
Host Objective
Host Message
Scanner
Transmission