CB3000 Client Bridge Install Guide
3
Verifying the Installation Site
Mounting options for the CB3000 include table top, wall or under a counter mounting using the
keyholes and mounting hardware provided with the unit.
Before installing the CB3000, verify the installation site meets the following requirements:
•
The Environmental Specifications as defined in the “
Technical Specifications on page -23
”
section of this guide.
•
The site should have access to a properly rated power source.
•
The site should be dry and within 100 meters of the device(s) (hub, telephone, computers,
point-of-sale) to be connected to the CB3000.
•
The site should not be near other equipment (transformers, fluorescent lights etc.) that could
interfere with the CB3000’s radio transmissions.
•
The site should be within 250 ft. of the wireless access point the CB3000 is targeting
for association.
Installing the CB3000
Cable and test the CB3000 before moving it to its table top, wall or under a counter operational
location. To cable the CB3000:
NOTE
A cross-over cable is not required to directly connect the CB3000 to a PC.
CAUTION
Do not connect a CB3000 (set to Infrastructure mode) directly to the
LAN supporting the WLAN the CB3000 is using (for example, through
a wall port). Such a connection could cause a transmission loop
between the CB3000 and its associated access point, disrupting
network connectivity.
!