10
Quadra ie m
Quadra ie FF m
Parameters
Natural gas LPG
Natural gas LPG
(G20)
Butan
Propan
(G20)
Butan
Propan
(G30)
(G31)
(G30)
(G31)
Lower Wobbe index (a 15°C-1013 mbar)
MJ/m
3
s
45,67
80,58
70,69
45,67
80,58
70,69
Lower heat value
MJ/m
3
s
34,02
116,09
88
34,02
116,09
88
MJ/kgs
-
45,65
46,34
-
45,65
46,34
Supply nominal pressure
mbar (mm H
2
O)
20 (203,9)
28-30 (285,5-305,9) 37 (377,3) 20 (203,9) 28-30 (285,5-305,9) 37 (377,3)
Supply minimum pressure
mbar (mm H
2
O) 13,5 (137,7)
-
-
13,5 (137,7)
-
-
Main burner (12 nozzles)
Ø mm
1,35
0,77
0,77
1,35
0,77
0,77
CH maximum gas capacity
m
3
/h
2,82
-
-
2,78
-
-
kg/h
-
2,10
2,07
-
2,07
2,04
DHW maximum gas capacity
m
3
/h
2,82
-
-
2,78
-
-
kg/h
-
2,10
2,07
-
2,07
2,04
CH minimum gas capacity
m
3
/h
1,10
-
-
1,18
-
-
kg/h
-
0,82
0,81
-
0,88
0,87
DHW minimum gas capacity
m
3
/h
1,10
-
-
1,04
-
-
kg/h
-
0,82
0,81
-
0,77
0,76
Maximum pressure downstream CH valve
mbar
10,10
28,00
36,00
10,10
28,00
36,00
mm H
2
O
102,99
285,52
367,10
102,99
285,52
367,10
Maximum pressure downstream DHW valve
mbar
10,10
28,00
36,00
10,10
28,00
36,00
mm H
2
O
102,99
285,52
367,10
102,99
285,52
367,10
Minimum pressure downstream CH valve
mbar
1,70
4,70
6,10
1,90
5,60
7,30
mm H
2
O
17,34
47,93
62,20
19,37
57,10
74,44
Minimum pressure downstream DHW valve
mbar
1,70
4,70
6,10
1,50
4,40
5,50
mm H
2
O
17,34
47,93
62,20
15,30
44,87
56,08
9.
MULTIGAS TABLE
24kW
Quadra ie m
Quadra ie FF m
Parameters
Natural gas LPG
Natural gas LPG
(G20)
Butan
Propan
(G20)
Butan
Propan
(G30)
(G31)
(G30)
(G31)
Lower Wobbe index (a 15°C-1013 mbar)
MJ/m
3
s
45,67
80,58
70,69
45,67
80,58
70,69
Lower heat value
MJ/m
3
s
34,02
116,09
88
34,02
116,09
88
MJ/kgs
-
45,65
46,34
-
45,65
46,34
Supply nominal pressure
mbar (mm H
2
O)
20 (203,9)
28-30 (285,5-305,9) 37 (377,3) 20 (203,9) 28-30 (285,5-305,9) 37 (377,3)
Supply minimum pressure
mbar (mm H
2
O) 13,5 (137,7)
-
-
13,5 (137,7)
-
-
Main burner (14 nozzles)
Ø mm
1,35
0,77
0,77
1,35
0,77
0,77
CH maximum gas capacity
m
3
/h
3,37
-
-
3,28
-
-
kg/h
-
2,51
2,48
-
2,44
2,41
DHW maximum gas capacity
m
3
/h
3,37
-
-
3,28
-
-
kg/h
-
2,51
2,48
-
2,44
2,41
CH minimum gas capacity
m
3
/h
1,13
-
-
1,34
-
-
kg/h
-
0,84
0,83
-
1,00
0,99
DHW minimum gas capacity
m
3
/h
1,13
-
-
1,11
-
-
kg/h
-
0,84
0,83
-
0,83
0,82
Maximum pressure downstream CH valve
mbar
10,40
28,00
36,00
10,20
28,00
36,00
mm H
2
O
106,05
285,52
367,10
104,01
285,52
367,10
Maximum pressure downstream DHW valve
mbar
10,40
28,00
36,00
10,20
28,00
36,00
mm H
2
O
106,05
285,52
367,10
104,01
285,52
367,10
Minimum pressure downstream CH valve
mbar
1,40
3,80
4,80
1,90
4,90
6,50
mm H
2
O
14,28
38,75
48,95
19,37
49,97
66,28
Minimum pressure downstream DHW valve
mbar
1,40
3,80
4,80
1,30
3,40
4,80
mm H
2
O
14,28
38,75
48,95
13,26
34,67
48,95
28kW