![Sygonix 2299888 Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/sygonix/2299888/2299888_operating-instructions-manual_1416756046.webp)
• Toggle mode: The changeover contact switches between
the two switch settings for each valid access attempt. For
example, this is optimal for arming/disarming an alarm
system..
Proceed as follows:
• The code lock must be in standby mode and the LED
indicator must be red.
• Enable programming mode (see section 11 "Programming",
paragraph "b) Enabling/exiting programming mode"). The
LED indicator will then flash red.
Example:
• Press the key. The LED indicator will light up orange.
• Enter the desired time/function:
= Toggle operation, output is switched
= Pulse operation, output is activated for 100 ms
-
= Output is activated for 55 seconds (example
).
• Press the button to confirm your entry. The LED indicator
will briefly turn green and then flash red (programming mode).
• To exit programming mode, press the key. The LED
indicator will switch to constant red to indicate that the code
lock is in standby mode.
46