e) Time Settings for Relay Function
This programming speci
fi
es for how long the relay is activated (factory settings: 5
seconds); a time from 00...99 seconds can be set.
The setting “00” has a special function. The relay is permanently activated. See
description below.
Start the programming mode as described in chapter 8. a). The yellow LED must
be lit.
Then enter:
*20 TT
(TT = activation time in seconds, 00...99)
Example 1:
The relay is activated for 2 seconds if the correct user code is entered later in
regular operation (green LED is lit). Then the relay is deactivated again. The
green LED goes out.
Example 2:
When the code lock is in regular operation again, the relay is permanently acti-
vated after any correct user code. The green LED is lit. The relay is deactivated
when any user code is entered again (this may also be another user code than
the one used for activating the relay). The green LED goes out.
If desired, you can programme other settings now or leave the programming
mode with the pound key (#).