SYCLOPE ALTICE'O Скачать руководство пользователя страница 1

 

 

 

 

 
 
 

 
 

 
 
 

 
 

 
 

 

 

 

 
 

 
 
 

 
 

 
 

 
 
 

 
 

 
 
 

 
 

 
 
 

 

Communication instructions 

 

 
 
 

 
 

 
 
 

 
 

 
 

 
 
 

Référence : ALT0000   

 

 

 

 

   

 

 

         Rev : 1 

SYCLOPE 

ALTICE’O 

®

 Controller for public swimming pools (Part 3) 

 

Содержание ALTICE'O

Страница 1: ...Communication instructions R f rence ALT0000 Rev 1 SYCLOPE ALTICE O Controller for public swimming pools Part 3...

Страница 2: ...tion SYCLOPE Electronique 2017 Manual of the 12 01 2017 Rev 1 Professional Analyzers Controllers for public swimming pools Product line ALTICE O Part 3 Communication instructions Ref DOC0357 Editor SY...

Страница 3: ...GSM Modem 9 4 Connection of the externat GSM Modem 10 5 Connection between EVASION and OPTILIGHT Erreur Signet non d fini IV Programming of the controller Erreur Signet non d fini 1 Communication RS48...

Страница 4: ...in this document must be strictly observed SYCLOPE Electronique S A S declines all responsibility in cases where failure to comply with the instructions of this documents is observed The following sy...

Страница 5: ...manufacturer Class of protection Manufacturer square code Identification of the manufacturer Conformity with the FCC part 15 Class B Serial number Identification plate 1 2 3 4 5 6 8 11 12 7 14 13 ALTI...

Страница 6: ...computer we offer a USB RS485 interface module Reference Designation INF1021 USB 485 converter 2 Connection between SYCLOPE EVASION controller and OPTILIGHT probe Connection to the SYCLOPE ALTICE O an...

Страница 7: ...order to connect your SYCLOPE ALTICE O to the Internet we offer several connection KIT Reference Designation KMD0020 Internal MODEM GSM GPRS kit with cable and local antenna KMD0040 Internal Ethernet...

Страница 8: ...on to the Internet the data are transmitted to the mysyclope com site and thus allow real time management of the operation of the SYCLOPE ALTICE O Alert messages can be sent to users via emails or SMS...

Страница 9: ...e BB RS485 Blue AA RS485 Black Ground LCL All units on the bus must be chained together Blue Terminal n 3 AA RS485 White Terminal n 4 BB RS485 Black Terminal n 5 Ground RS485 Configuration All switche...

Страница 10: ...ns 3 Connection of the internal GSM Modem The PIN code of the SIM card must be deactivated 4 Connection of the externat GSM Modem 5 6 4 Tx Brown 5 Rx Red 6 GND Yellow SIM card GSM Module Aadaptation p...

Страница 11: ...odem IP Connections Color code EIA 568B WIFI Socket MODEM WIFI antenna Antenna cable ETHERNET Socket MODEM Network Link Cable 9 Ground 8 Brown 7 Brown White 6 Blue 5 Blue White 4 Orange 3 Orange White...

Страница 12: ...roller on which the master is connected Speed Press left and right arrows to change the communication speed on the bus Parity Press left and right arrows to select the parity of the data exchange Stop...

Страница 13: ...to open the alphanumeric keypad and enter the address you will have received Port This port is set by default and there is no need to change it except on request of the SYCLOPE Electronique support T...

Страница 14: ...rinciple as above Gateway Same principle as above Automatic DNS If the local Ethernet network on which the controller is connected automatically distributes the DNS you must check this box In this cas...

Страница 15: ...ructure Network on which multiple elements can connect Ad Hoc Network on which only the controller will be connected Security Press left and right arrow keys to select the security mode of your wirele...

Страница 16: ...slave Controller Other controller of the brand SYCLOPE Electronics with modbus function Ultrafiltration Ultrafiltration system of the brand SYCLOPE Electronique You can program up to 5 different slav...

Страница 17: ...a the RS485 bus remotely via telephone line and or via the mysyclope com website The software is free in its local communication version and subject to license in the remote version Software Setup Acc...

Страница 18: ...Connection via RS485 BUS Select the Port Com used on your computer Select speed Same as the device connected to the BUS Select the parity Same as the device connected to the BUS Via internet Internet...

Страница 19: ...onnected controller To read a file of an old configuration already used and saved To save in a file the actual configuration to upload later Programming by the software does not allow the calibration...

Страница 20: ...ify the port the speed the parity as well as the number ModBus address of the controller These configurations correspond to the CONFIGURATION MODBUS directly accessible on the controller WARNING If yo...

Страница 21: ...as the identifier of the controller on the website Check the settings Server www mysyclope com Port 18880 The Access Point Name APN depends on your chip card provider Do not forget to ask to be able...

Страница 22: ...ere you enter IP Address Subnet Mask and Gateway Enter the DNS of your internet provider Enter all the parameters of your WIFI connection Check the settings Server mysyclope com Port 18880 e Controlle...

Страница 23: ...LOPE Electronics technical service Give the serial number of the device Give the name of the person in charge of the communication system Give your email address The technical service adds your contro...

Страница 24: ...enance with SYSCOM V3 Page 24 28 Programming communication instructions Click on the Systems tab on the left side panel Browse the sites and or connected devices The data sent by the device are now re...

Страница 25: ...it you should use the notation register Register below 40000 1 Format o unsigned integer Integer of size 16bits 1 register without sign value from 0 to 65535 o unsigned long Integer of size 32bits di...

Страница 26: ...Conditions of computed entries 40019 unsigned integer 1 R Binary of working condition of E11 E18 Measurement value of E1 40020 inverted float 2 R Temperature value Measurement value of E2 40022 inver...

Страница 27: ...nverted float 2 R Xx value according to programming Computed value of E12 40057 inverted float 2 R Xx value according to programming Computed value of E13 40059 inverted float 2 R Xx value according t...

Страница 28: ...tructions SYCLOPE Electronique S A S Z I A ropole pyr n es Rue du Bruscos 64 230 SAUVAGNON France Tel 33 0 559 337 036 Fax 33 0 559 337 037 Email contact syclope fr Internet http www syclope fr 2017 b...

Отзывы: