HYDRO’pH
®
,
HYDR’ORP
®
,
HYDRO’pH Duo
®
and
HYDRO’pH/ORP
®
instructions
Procedure:
=> = General reset
Reminder of « Factory » settings:
Cancellation of pH4 and pH7 calibrations
Cancellation of Zero ORP and 465mV calibrations
Setting to 120 minutes for the pH pump running time
Setting to 120 minutes for the oxidizing pump running time
Setting of pH set point to 7,40
Setting of ORP set point to 750mV
Setting of the operating band of the pH controller between 6,8 and 7,8pH
Setting to x20 for the pH proportional band before the V2.12 realise …
Or setting to 0,8pH for the proportional band since V2.12 realise
Setting to x50 for the ORP proportional band before the V2.12 realise …
Or setting to 30mV for the proportional band since V2.12 realise
Errors reset
Cancellation of errors memorization
Selecting the display mode of pH
Setting the display brightness to the maximum
CAUTION:
This procedure must be performed by a qualified technician.
All calibration operations must be resumed.
The settings in hidden mode must also be reconfigured according to
the pool if necessary.