Changing the internal protection fuse
DANGER:
Before changing the fuses, cut power supplies.
Procedure for changing fuses:
1. Cut the primary power supply
2. Locate the fuse to change according to the diagram
3. Change the fuse with an identical fuse
4. Replace the front cover and fixation screws.
5. Commission the equipment.
DANGER:
Fuse replacement must be performed by a qualified technician!
CAUTION:
Deteriorated fuses must imperatively be replaced by fuses of identical
intensity and technology!
NOTE:
If a fuse is destroyed, it is imperative to identify the cause before
replacing it!
4-6
Filling the tanks of chemicals
NOTE:
The chemicals used in pools can be dangerous and corrosive!
They can damage your health and cause environmental damages.
Any mixture of chemicals can be hazardous to health and should
never be done!
NOTE:
The products can also be « ready-prepared ». In this case, right introduce
directly the valve in the tank.
Before opening the box, cut the primary power supply!
ELECTRICAL
HAZARD
Glass fuse 5x20
160mA Time-lag