Remove the two
5
∕
16
in. bolts securing the pump mounting
bracket.
Slide the pump and pump bracket assembly out
of the
pump well. It is not necessary to disconnect any electrical
cables.
When the pump is free of the housing, rotate it upward and
out of the pump well to more easily access the check valve.
NOTICE: Take care not to bend or damage the
“marshmallow” float assembly.
Clean and inspect the check valve.
Using a
9
∕
16
in wrench,
unthread the check valve fitting and remove it from the
pump.
Using small-jawed pliers, carefully remove the valve
compression fitting and the “duckbill” valve.