Command Code 

Function 

/%[Y]/[X]:[Z]. 

HDCP management command. [Y] is the input (value: I) or output (value: 
O). [X] is the number of the port, if the value of X is ALL, it means all 
ports. [Z] is for working status (value: 1 or 0). 

Y=I & Z=1, sets the input port to HDCP enabled. 

Y=O & Z=1, sets the output port to HDCP enabled. 
Y=I & Z=0, sets the input port HDCP disabled. 

Y=O & Z=0, sets the output port to HDCP disabled. 

[x1]R[x2].  

Transfer the IR signal from input channel [x1] to output channel [x2]. 

DigitAudioON[x]. 

Enable HDMI audio output of port x. 

[X]=1, 2, 3, 4, 5, 6, 7, 8, enable this port. 

[X]=9, enable all the 8 ports. 

DigitAudioOFF[x]. 

Disable HDMI audio output of port x. 

[X]=1, 2, 3, 4, 5, 6, 7, 8, disable this port. 

[X]=9, disable all the 8 ports. 

/+[Y]/[X]:******. 

Set communication between PC and HDBT receiver. 

1.

 

[Y] is for RS232 port on the HDBT receiver 

Value = 1,2,3,4,5,6,7,8,A,B,C,D,E,F,G or H 

The value of [Y] is defined into the following meanings (with a given 
baud rate stated by the value of [X]): 

a.

 

[Y] = 1, 2, 3, 4, 5, 6, 7, or 8, send this command to the 

corresponding HDBT receiver to control far-end device. 

b.

 

[Y] = 9, send this command to all HDBT receivers to control all 

far-end devices. 

c.

 

[Y] = A, B, C, D, E, F, G or H 

 

(HDBT PWON commands) 

d.

 

[Y] = I, J, K, L, M, N, O or P 

 

(HDBT PWOFF commands) 

For items c or d, send this command, it will be saved by the 

matrix switcher and not sent to the corresponding HDBT 
receiver. 
The command functions will be sent after the matrix receives 

with the PWON command (for item c) or the PWOFF command 

(for item d). 

Note: 

A & I are for port 1.    B & J are for port 2. 

 

 

C & K are for port 3.    D & L are for port 4. 

 

 

E & L are for port 5.    F & N are for port 6. 

 

 

G & O are for port 7.    H & P are for port 8. 

2.

 

[X] is the baud rate (Value ranges from 1 to 7, 1 is for 2400, 2 for 
4800, 3 for 9600, 4 for 19200, 5 for 38400, 6 for 57600 and 7 for 

115200) 

3.

 

***** is represents the data up to a maximum of 48 bytes. 

4.

 

The symbol “.” is the end of 

the command. If there are some 

symbols of 

“.” in one command, this case is allowed and the last one 

is the end. 

EDIDH[x]B[y]. 

Study the EDID from output port [x] to input port [y]. 
If the EDID data is effective and the audio part supports not only PCM 

mode, then force-set it to support PCM mode only. If the EDID data is 
not effective, then set it as initialized EDID data. 

EDIDPCM[x]. 

Set the audio part of input port [x] to PCM format in EDID database. 

EDIDG[x]. 

Get EDID data from the output port and display the output port number 

of X. 

EDIDMInit. 

Recover the factory default EDID data. 

EDIDM[X]B[Y]. 

Manually EDID switching. Enable input[Y] to study the EDID data of 
output[X]. If the EDID data is not effective, then set it as initialized EDID 

data. 

Содержание MHDBT-88P

Страница 1: ...t 7 Worrall Street Salford Greater Manchester M5 4TH United Kingdom Tel 44 0 161 868 3450 Fax 44 0 161 868 3459 www sy co uk Installation Guide 8 x 8 HDMI Matrix Switcher with HDBT PoC Outputs 8 HDMI...

Страница 2: ...orts PoC providing power for all the receivers connected to the HDBT outputs x Supports multiple control methods front panel RS232 IR and optional TCP IP control x Multiple EDID management x LCD shows...

Страница 3: ...HDMI output devices for local monitoring HDBT Output extension ports works with HDBT receivers for example SY HDBT 70PR SY HDBT 100R RS232 Serial port for controlling the matrix IR ALL IN IR control...

Страница 4: ...nal can be transmitted bi directionally 7 The MHDBT 88P can be controlled by its built in IR receiver or through the IR EYE port by connecting with external IR receiver The IR signal can also be trans...

Страница 5: ...ut 4 All input ports copy the EDID data from one output port Operation EDID ALL OUTPUT ENTER Example All input ports read EDID data from output 4 Predefined EDID Settings There are four types of embed...

Страница 6: ...is not Check the output resolution Use button to check all the 8 output resolutions Output Check Press any output button to check its corresponding input Example To check which input is connected to o...

Страница 7: ...t channel number of the MHDBT 88P There must be an HDBT receiver with an IR detector connected Example Send the RS232 command 3R2 to transfer the received IR signal from zone 2 to IR OUT port 3 Note W...

Страница 8: ...BT receiver which must have an IR transmitter connected When the IR receiver is connected to IR ALL IN port the IR signal is simultaneously sent to all 8 HDBT receivers each of which must have an IR t...

Страница 9: ...ideo player the HDBT 8x8 matrix etc from the remote location In this case the IR signal received from the HDBT receiver will be transmitted to the corresponding IR OUT port of the MHDBT 88P as shown b...

Страница 10: ...like1 1 1 2 8 7 8 8 1 1 and so on The switching interval is 2 seconds Undo To cancel the previous operation x All Transfer signals from the input channel x to all output channels All Transfer all inpu...

Страница 11: ...M N O or P HDBT PWOFF commands For items c or d send this command it will be saved by the matrix switcher and not sent to the corresponding HDBT receiver The command functions will be sent after the m...

Страница 12: ...ent by port 4 when PWON 9955 Check the command sent by port 5 when PWON 9956 Check the command sent by port 6 when PWON 9957 Check the command sent by port 7 when PWON 9958 Check the command sent by p...

Страница 13: ...MHDBT 88P sy co uk 13 4 Type the command carefully it is case sensitive...

Страница 14: ...32 control software and with the right communication settings you are able to control the MHDBT 88P Local Control of the MHDBT 88P Control the MHDBT 88P from local Control the MHDBT 88P from Remote Lo...

Страница 15: ...Device through 9 pin female RS232 port Control 3rd Party Device from Remote Location By connecting the 3 way captive screw RS232 port on the HDBT receiver to a PC or the controlled device the RS232 si...

Страница 16: ...ID data and manual EDID management Audio Output Stereo Analogue and Digital HDMI Control Interfaces RS232 and IP Power Supply 110V 240V AC 50 60 Hz Power Consumption Fully Loaded 117 8 W Unloaded 54 4...

Страница 17: ...has sufficient power to supply the device it is connected to 2 Do not operate either of these products outside the specified temperature and humidity range given in the above specifications 3 Ensure t...