SWT TECH Series Скачать руководство пользователя страница 6

Page 6

Table 7

DIR/Time Clock Options

*  Day Override and Gallon Capacity can not both be set to “oFF” at the same time. 

For DIR Softeners, there are two options for setting the Gallons Capacity. The Gallons Capacity is automatically 

calculated if set to “AUTO.” Reserve Capacity is automatically estimated based on water usage if “AUTO” is used. 

The other option is to set the Gallons Capacity to a specific number. If a specific number is set, Reserve Capacity is 

0 (zero), unless the value is manually set (i.e. the manufacturer intentionally sets the Gallon Capacity number below 

the calculated capacity of the system).

The Tech WS1 & WS1.25 Control Valves can also be set to regenerate immediately or at the next regeneration time 

by changing the Regeneration Time Option. There are three choices for settings:

1.  “NORMAL” means regeneration will occur at the preset regeneration time.

2.  “on 0” means regeneration will occur when the Gallons Capacity reaches 0 (zero).

3.  “NORMAL” and “on 0” ( on 0) means the regeneration will occur at the preset regeneration time 

unless the Gallons Capacity reaches 0 (zero). If the Gallons Capacity reaches 0 (zero), the regeneration will 

begin 10 minutes after no water usage.

The user can initiate manual regeneration. The user has the option to request the manual regeneration at the 

delayed regeneration time or to have the regeneration occur immediately:

1.  Pressing and releasing the REGEN button will flash “Regen Today” on the display and the regeneration will occur 

at the delayed regeneration time. The user can cancel the request by pressing and releasing the REGEN button. 

This method of manually initiating regeneration is not allowed when the system is set to “on 0” (i.e. to 

immediately regenerate when the Gallon Capacity reaches zero).

2.  Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration. 

The user cannot cancel this request, except by resetting the control by pressing NEXT and REGEN buttons 

simultaneously for 3 seconds.

A unique feature of this control valve is the ability to display actual water usage for the last 63 days. The values are 

initially stored as “----”. This means the value is unknown. As days pass, values are stored as “0” for no flow or the 

actual number of gallons. The counting of the gallons starts at the regeneration time. If no regeneration time can be 

set (i.e. when the valve is set for immediate regeneration) the counting of gallons starts at 12 a.m. Day 1 is 

yesterday, day 2 the day before yesterday, etc. As new values are added, the oldest history disappears.

Another unique feature is that the valve automatically calculates a Reserve Capacity when set up as a softener with 

Gallons Capacity set to “AUTO” and the Regeneration Time Option set to “Normal” or “ on 0.” The actual 

Reserve Capacity is compared to the Gallons Capacity remaining immediately prior to the preset regeneration time. 

A regeneration will occur if the actual Reserve Capacity is less than the Gallons Capacity remaining. The actual 

Reserve Capacity is calculated by using the estimated Reserve Capacity and adjusting it up or down for actual 

usage.

The estimated Reserve Capacity for a given day of the week is the maximum value stored for the last three non-

trivial water usages (i.e. more than 20 gallons/day) in seven day intervals.

DIR

Time Clock

Reserve Capacity 

Softener

Filter 

Settings *

Regenerant

Backwash 

Only

Day Override

Gallon Capacity

Yes 

Automatically calculated 

Yes 

Off 

Auto

Yes

If desired enter a value less than 

estimated capacity

Yes 

Yes 

Yes 

Off

Any Number

Yes 

Yes 

Automatically calculated 

Yes

Any Number

Auto

Yes 

Yes

If desired enter a value less than 

estimated capacity

Yes 

Yes 

Yes

Any Number

Any Number

Yes 

None 

Yes 

Yes 

Yes

Any Number

Off

Содержание TECH Series

Страница 1: ...I n c O P E R A T I O N I N S T R U C T I O N M A N U A L TECH SERIES CONTROL VALVES F I L T E R S S O F T E N E R S C O N D I T I O N E R S 1 INCH TECH SERIES CONTROL VALVE MODEL WS1 1 25 INCH TECH SERIES CONTROL VALVE MODEL WS1 25 APRIL 2016 ...

Страница 2: ...Clock Options 7 General Instructions 8 Softener Setup 9 Table 8 Softener and Filter Setting Options 10 Filter Setup 11 Installer Display Settings 12 User Display Settings 12 General Operation 12 Regeneration Mode 12 Manual Regeneration 13 Set Time of Day 13 Power Loss 14 Error Message 14 Diagnostics 15 Valve History 16 Drawings and Part Numbers 16 Front Cover and Drive Assembly 17 WS1 Drive Cap As...

Страница 3: ...r tube can be cut 0 5 inch above to 0 5 inch below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC adapter power pack comes with a 15 foot power cord and is designed for use with the control valve The AC adapter power pack is for dry location use only The control valve remember...

Страница 4: ...reated water is still available For example If a downflow filter regeneration time is set for 2 00 a m with the prefill option selected then the fill cycle occurs at 12 00 a m and the start of the backwash cycle occurs at 2 00 a m There is only one rinse Backwashes can be set to NORMAL or LONGER The option selected will apply to all backwashes Tables 5 and 6 page 5 show the length of the cycles wh...

Страница 5: ...ity should be set to oFF 2 See Installer Display Settings Step 3 NA page 11 Softener Setup Step 6 SS page 8 and Filter Setup Step 5 FS page 10 for explanations of Day Override and Gallon Capacity WS1 WS1 25 Single Backwash WS1 WS1 25 Double Backwash NORMAL LONGER NORMAL LONGER Backwash 14 16 8 12 Regenerate 60 60 60 60 2nd Backwash 10 12 Rinse 8 10 8 10 Total 82 86 86 94 WS1 WS1 25 Single Backwash...

Страница 6: ...ing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration The user cannot cancel this request except by resetting the control by pressing NEXT and REGEN buttons simultaneously for 3 seconds A unique feature of this control valve is the ability to display actual water usage for the last 63 days The values are initially stored as This means the value is unk...

Страница 7: ...isplay Any changes made prior to the five minute time out are incorporated The one exception is the current flow rate display under the diagnostic procedure The current flow rate display has a 30 minute time out feature To quickly exit Softener Setup Filter Setup Installer Display Settings Diagnostics or Valve History press SET CLOCK Any changes made prior to the exit are incorporated All informat...

Страница 8: ...capacity and water hardness oFF bases regeneration on Day Override in Step 3 NA page 11 or number of gallons 20 to 50 000 gallons See Table 8 page 9 for more detail 3 Press NEXT to go to Step 7 SS Press REGEN to return to the previous step STEP 7 SS Refill Set refill option using or buttons PoST to refill the brine tank after the final rinse or PrE to refill the brine tank two hours before the reg...

Страница 9: ...ons is reached AUTO on 0 oFF Reserve capacity not automatically estimated Regeneration occurs immediately when gallons capacity reaches 0 Time of regeneration will not be allowed to be set because regeneration will always occur when gallons capacity reaches 0 Any number on 0 oFF Reserve capacity not automatically estimated Regeneration occurs immediately when gallons capacity reaches 0 Time of reg...

Страница 10: ...h LONGER for one longer backwash 16 minutes or LONGER 2 for two longer backwashes 12 minutes each See Tables 5 and 6 page 5 for additional details Press NEXT to go to Step 5 FS Press REGEN to return to the previous step STEP 5 FS Gallons Capacity Set gallons capacity using or buttons oFF bases regeneration on Day Override in Step 3N page 11 or number of gallons 20 to 50 100 gallons See Table 8 pag...

Страница 11: ...mber of days between regeneration 1 to 28 a regeneration initiation will be called for on that day even if a sufficient number of gallons were not used to call for a regeneration or oFF regeneration initiation is based solely on gallons used Press NEXT to go to step 4 NA Press REGEN to return to the previous step STEP 4 NA Next Regeneration Time hour Set the hour of day for regeneration using or b...

Страница 12: ...egeneration process and the time remaining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regeneration There may be a period of heavy water...

Страница 13: ... Step 3 UD STEP 3 UD Current Time minutes Set the minutes of the day using or buttons Press NEXT to exit Set Clock Press REGEN to return to previous step Power Loss If the power goes out the system will keep time for up to 8 hours or until the battery is depleted If a power outage of more than 8 hours occurs the time of day will flash on and off which indicates the time of day should be reset The ...

Страница 14: ...aximum number of gallons treated for the last 63 days This display will show dashes if a water meter is not installed Press NEXT at any time to go to Step 6 DA Press REGEN to return to the previous step STEP 6 DA Flow Rate current Turn the water on at one or more taps in the building The flow rate in gallons per minute will be displayed If flow stops the value will fall to 0 zero in a few seconds ...

Страница 15: ...STEP 4 VH Gallons total used since start up This display shows the total gallons treated since start up This display will equal 0 zero if a water meter is not installed Press NEXT to go to Step 5 VH Press REGEN to return to the previous step STEP 5 VH Days total since start up This display shows the total days since start up Press NEXT to go to Step 6 VH Press REGEN to return to the previous step ...

Страница 16: ... VAC 230 VAC Supply Frequency 60 Hz 50 Hz Output Voltage 12 VAC 12 VAC Output Current 500 mA 500 mA Drawing No Part No Description Quantity 1 LC V3175 01 WS1 Front Cover Assembly 1 LC V3002 WS1 Drive Assembly 1 2 LC V3107 01 WS1 Motor 1 3 LC V3106 01 WS1 Drive Bracket and Spring Clip 1 4 LC V3108 10BOARD WS1 PC Board XMEGA Replace 1 5 LC V3110 WS1 Drive Reducing Gear 12 x 36 3 6 LC V3109 WS1 Drive...

Страница 17: ...ty 1 LC V3005 02 WS1 Spacer Stack Assembly 1 2 LC V3004 Drive Cap Assembly 1 3 LC V3178 WS1 Drive Backplate 1 4a LC V3011 WS1 Piston Downflow Assembly 1 4b LC V3011 01 WS1 Piston Upflow Assembly 1 5 LC V3174 WS1 Regenerant Piston 1 6 LC V3135 O ring 228 1 7 LC V3180 O ring 337 1 8 LC V3105 O ring 215 Distributor Tube 1 Not Shown LC V3001 WS1 Body Downflow Assembly 1 LC V3001 02 WS1 Mixing Valve Bo...

Страница 18: ...sembly 1 4b LC V3011 01 WS1 Piston Upflow Assembly 1 5 LC V3174 WS1 Regenerant Piston 1 6 LC V3135 O ring 228 1 7 LC V3180 O ring 337 1 8 LC V3358 O ring 219 Distributor Tube Opening 1 32 inch 1 LC V3357 O ring 218 Distributor Tube Opening 32mm 1 Not Shown LC V3020 WS1 25 Body Downflow Assembly Distributor Tube Opening 1 32 inch 1 LC V3020 01 WS1 25 Mixing Valve Body Downflow Assembly Distributor ...

Страница 19: ...iston is black and amber NOTE The WS1 downflow piston is a solid amber color The WS1 upflow piston is black and amber 1 25 inch 1 5 inch Spacer Color Black Spacer Color Gray 1 5 inch 1 25 inch Black Plug Spacer Color Gray 1 25 inch DOWNFLOW BACKWASH UPFLOW 1 25 inch Gray Plug Gray Ring Gray Distributor O ring Retainer NOTE The WS1 downflow piston is a solid amber color The WS1 upflow piston is bla...

Страница 20: ... U F F C I T Y B O U L E V A R D E L G I N I L 6 0 1 2 0 U S A T E L E P H O N E 8 4 7 8 8 8 6 9 0 0 F A C S I M I L E 8 4 7 8 8 8 6 9 2 4 E M A I L i n f o s w t w a t e r c o m W E B S I T E w w w s w t w a t e r c o m FORM TECH MANUAL EFFECTIVE APRIL 2016 ...

Отзывы: