Page 15
Valve History
STEP 1-VH
– Press
and
simultaneously for 3 seconds and release. Then
press
and
simultaneously again and release. If screen in Step 2-VH does
not appear in 5 seconds, the lock on the valve is activated. To unlock, press
,
NEXT,
, and SET CLOCK in sequence, then press
and
simultaneously
for 3 seconds and release. Then press
and
simultaneously again and
release.
STEP 2-VH
–
Software Version:
This display shows the software version of the
valve. Press NEXT to go to Step 3-VH. Press REGEN to exit Valve History.
STEP 3-VH
6
–
Flow Rate, maximum since start-up:
This display shows the
maximum flow rate in gallons per minute that has occurred since start-up. This
display will equal 0 (zero) if a water meter is not installed. Press NEXT to go to
Step 4-VH. Press REGEN to return to the previous step.
STEP 4-VH
–
Gallons, total used since start-up:
This display shows the total
gallons treated since start-up. This display will equal 0 (zero) if a water meter is
not installed. Press NEXT to go to Step 5-VH. Press REGEN to return to the
previous step.
STEP 5-VH
–
Days, total since start-up:
This display shows the total days since
start-up. Press NEXT to go to Step 6-VH. Press REGEN to return to the
previous step.
STEP 6-VH
–
Regenerations, total number since start-up:
This display shows
the total number of regenerations that have occurred since start-up. Press NEXT
to go to Step 7-VH. Press REGEN to return to the previous step.
STEP 7-VH
–
Error Log:
This display shows a history of the last 10 errors
generated by the control during operation. Press the
or
buttons to review
each error recorded. Press NEXT to exit Valve History. Press REGEN to return
to the previous step.
Step 1-VH
Step 2-VH
Step 3-VH
Step 4-VH
Step 5-VH
Step 6-VH
EXIT VALVE HISTORY
Step 7-VH
6. Values in Steps 3-VH through 7-VH cannot be reset.