4 Technical Specifications
Sensor
Measurement objects
Solid particles in a gas flow
Particle size
0,3
µ
m or larger
Measurement range
From 0.1 mg/m3
Range setup
Automatic
Process Temperature
Max. 140 °C
Ambient temperature
-20…+60 °C
Pressure
Max. 2 bar
Gas velocity
Min. 4 m/s
Humidity
95% RH (non-condensing)
Meassurement principle Tribo-electricity (elektrostatic detection)
Damping time
10 sec
Output signals
• 2 solid switching contact states (max. current feed of 170 mA)
• 3-colour LED in the front cover
Alarm settings
Alert – 5x normal dust level
Alarm – 20 x normal dust level
Sensor rod
Stainless steel; length: 220 mm
Enclosure
Aluminium
Protection category
IP 65; dustEx 22 (optional)
Power supply
12–24 VDC
Power consumption
3W
Electrical connections
2 m cable; M12 connector (optional)
Cable (power + signal)
8 wires (shielded)
Process connection
R 1/2” male thread
Weight
Approx. 0.7 kg
This instrument conforms to the following standards:
Product standard – electrical equipment for measurement, control and
laboratory use – EMC requirement
Reference standard EN 61326
Publication year (1997);
Amendment(s) A1(1998), A2(2001), A3(2003)