SWP 9032H Скачать руководство пользователя страница 9

STEALTH DIGI-CUT 100 CNC

9

4  OPERATION CONTROL AND CONNECTORS

1. 

Cutting current regulator – used to regulate the current when cutting.

2. 

Power pilot lamp

3. 

Over-current / Over-heat alarm – when over-heat or over-current, the lamp would is lit.

4. 

Current display

5. 

Cutting gun incorrect installation and air pressure low alarm

6. 

Barometer display

7. 

Work lamp – turn on the switch of the cutting gun, generate the voltage, the lamp on

8. RUN/SET – when cutting the workpiece, turn to ‘RUN’. When performing a gas test, 

 

turn to ‘SET’.

9. 

Cutting gun connector – connect to the cutting machine.

10.  Remote control plug
11.  Positive output cable
 – connect to the workpiece.
12. Barometer – ensure there is no impurity and moisture in the compressed air.
13.  Power cable – connect to the appropriate power supply.
14.  Power switch – turn on or off the power source.

   

7   

§4 Operation 

4.1 Layout Of The Front And Rear Panel: 

   

Fig 4.1 schematic drawing of the front panel and rear panel 

   

1.Cutting current regulator: 

it is used to regulate the current when cutting.

 

2. Power pilot lamp 
3. Over-current ,over-heat alarm :

when over-heat, over-current, the lamp would be on. 

4.Current display 
5.Cutting gun improper installation and air pressure low alarm 
6.Barometer display 
7. Work lamp: 

turn on the switch of the cutting gun, generate the voltage, the lamp on

 

8. RUN/SET: 

when cutting the workpiece, turn to the “RUN”; when doing gas test, turn to the “SET”.

 

9.Cutting gun connector: 

connected to the cutting machine 

10.remote control plug

 

11.Positive output cable: 

connected to the workpiece 

12.Barometer :

ensure there are no impurity and moisture in the compressed air 

13.Power cable: 

connected to the appreciate power supply 

14.Power switch: 

turn on or off the power source 

Содержание 9032H

Страница 1: ...Part No 9032H DIGI CUT 100 CNC OPERATOR S MANUAL...

Страница 2: ...al completely before attempting to use this equipment Save this manual and keep it handy for quick reference Pay particular attention to the safety instructions provided for your protection Contact yo...

Страница 3: ...8 3 3 GAS CONNECTIONS 8 4 OPERATION CONTROL AND CONNECTORS 9 4 1 CUTTING PREPARATION 10 4 2 CUTTING OPERATION 10 4 3 ALARM INDICATOR 11 4 4 ABOUT THE CUT VOLTAGE DIVIDER 11 5 MAINTENANCE AND TROUBLESH...

Страница 4: ...ions that may i function of cardiac pacemakers hearing aids or other electronic health equipm near plasma arc cutting applications should consult their medical health qualifi manufacturer of the healt...

Страница 5: ...rn your skin The plasma arc process produ violet and infra red light These arc rays will damage your eyes and burn your skin if you are not To protect your eyes always wear a cutting helmet or shield...

Страница 6: ...by inverter device discrete IGBT after reducing voltage by medium transformer the main transformer and rectified by medium frequency rectifier fast recovery diode and is outputted by inductance filter...

Страница 7: ...nformation 2 2 Features 2 3 1 IGBT parallel balanced current technology and digital control technology 2 3 2 Wider input voltage flexibility provides peak performance power under variable conditions 1...

Страница 8: ...1Unpacking Use the packing lists to identify and account for each item 1 Inspect each item for possible shipping damage If damage is evident contact your distributor and or shipping company before pr...

Страница 9: ...oisture in the compressed air 13 Power cable connect to the appropriate power supply 14 Power switch turn on or off the power source 4 1LayoutOfTheFrontAndRearPanel Fig 4 1 schematic drawing of the fr...

Страница 10: ...s and loosen the trigger quickly the gas stops you can then hold down the trigger to restart the machine 4 2 Cutting Operation 8 4 2CuttingPreparation 1 Tightly connect the power cable to electrical s...

Страница 11: ...ed with an optional factory installed four position voltage divider that is designed to be safely connected without tools The built in voltage divider provides a scaled downarc voltage of 20 1 30 1 40...

Страница 12: ...computerproducts Note The cover on the machine interface receptacle prevents dust and moisture from damaging the receptacle when not in use This cover should be replaced if damaged or lost Installatio...

Страница 13: ...Turn OFF the power supply and disconnect the power cord 2 Remove the power supply cover 3 Locate the voltage divider DIP switches on the left side of the power supply Shift and Scale Selection Dial Sc...

Страница 14: ...t properly installed Turn off the power source and install the shield cup securely Turn on the power source 5 1 4 The temperature indicator lights up after the machine has only been on for a short tim...

Страница 15: ...echnician repair it 5 2 4 Arc shuts off during operation and will not restart when torch is triggered 5 2 4 1 Power Supply is overheated OC OT lamp lit Let unit cool down for at least five minutes Ens...

Страница 16: ...cutting speed 5 3 3 3 Excessive oil or moisture in torch Hold torch 3 mm from clean surface while purging and observe oil or moisture build up do not activate torch If there are contaminants in the g...

Страница 17: ...17 STEALTH DIGI CUT 100 CNC 6 MAIN ELECTRICAL DIAGRAM Appendix 1 Electrical principle drawing...

Страница 18: ...SE 9030H 9032H 09 REAR PANEL 9032H 13 BASE 9032H 22 FRONT PANEL 9032H 25 CENTRAL SOCKET USE 9030H 17 9032H 27 KNOB USE 9000H 33 9032H 29 FRONT PCB 9032H 31 CONTROL PCB 9032H 33 SOLENOID VALVE 9032H 38...

Страница 19: ...STEALTH DIGI CUT 100 CNC 19...

Страница 20: ...STEALTH DIGI CUT 100 CNC Specialised Welding Products Ltd Unit 1 Farringdon Industrial Centre Farringdon Nr Alton Hampshire GU34 3DD UK tel 44 0 1420 588180 fax 44 0 1420 588184 email sales swp uk net...