DIGI-CUT 100 CNC
Power Supply Voltage (V)
3~400±10%
Frequency Hz
50/60
Rated input current (A)
28
Rated input power (Kw)
14.5
Adjustment range of current (A)
20~100
Max no-load voltage (V)
420
Duty cycle (40ºC / 10 minutes)
100A @ 80%
Severance Cut for Carbon Steel (mm)
≤
60
Carbon Steel
≤
45
Optimal cutting
Stainless Steel
≤
45
thickness (mm) Aluminium
≤
36
Copper
≤
20
Dimensions (mm) L x H x W
630 x 240 x 445
Protection class
IP23
Insulation class
H
Net weight (Kg)
30.5
Cooling method
AF
STEALTH DIGI-CUT 100 CNC
7
Table 2.1 Technical information
2.2 Features
2.3.1 IGBT parallel balanced current technology and digital control technology.
2.3.2 Wider input voltage flexibility provides peak performance power under variable
conditions (±15%) for steady cuts.
2.3.3 EMI filter restrains the EMI transmission of the power.
2.3.4 Starts without high-frequency so it will not interfere with controls or computers.
2.3.5 Pilot Arc Controller increases cutting capabilities and speeds, and improves tip
life.
2.3.6 Various protective and alarm functions over-temperature and over-current allow
faster troubleshooting and eliminates unnecessary downtime.
2.3.7 Back striking tip and electrode ensure velocity of striking and quality of arc for
prolonged usage.