STEALTH DIGI-CUT 100 CNC
12
NOTE
The cover on the machine interface receptacle prevents dust and moisture
from damage when not in use. This cover should be replaced if damaged or
lost. Installation of the machine interface cable must be performed by a
qualified service technician. To install a machine interface cable:
1. Turn OFF the power and disconnect the power cord.
2. Remove the machine interface receptacle’s cover from the rear of the
power supply.
3. Connect the machine interface cable to the power supply.
Refer to the following table when connecting the CUT system to a torch height controller or
CNC controller with a machine interface cable.
Signal
Type
Instruction
Connector socket Cable ends
Normally open.
18 VDC open circuit voltage
Start (start
Input
at START terminals.
8, 9
8 (yellow
plasma)
Requires dry contact closure
9 (green)
to activate.
Normally open. Dry contact
Transfer (start
closure when the arc transfers.
machine
120 VAC/1 A maximum at the
13 (blue)
motion)
Output machine interface relay or
13, 14
14 (white)
switching device (supplied by
the customer).
Ground
Ground
CUT: Divided arc signal of
6 (red)
Voltage
Output 20:1, 30:1, 40:1, 50:1
6 (+), 7 (–)
7 (black)
divider
(provides a maximum of 18 V).
10
with the machine interfacewiring. The voltage divider is not fault tolerant and
ELV outputs do not comply withsafety extra low voltage (SELV) requirements
for direct connection to computerproducts.
Note
:
The cover on the machine interface receptacle prevents dust and moisture from damaging the receptacle
when not in use. This cover should be replaced if damaged or lost.
Installation of the machine interface cable must be performed by a qualified service technician. To install a
machine interface cable:
1. Turn OFF the power and disconnect the power cord.
2. Remove the machine interface receptacle’s cover from the rear of the power supply.
3. Connect the machine interface cable to the power supply.
1
3
4
7
8
11
12
14
Divider output
The large arc
signal connection
Gun switch signal
connection
The small arc
signal connection
Refer to the following table when connecting the CUT system to a torch height controller or CNC controller
with a machine interface cable.
signal
type
Instruction
The connector socket Cable ends
Start (start
plasma)
Input
Normally open.
18 VDC open circuit voltage at
START terminals.
Requires dry contact closure to
activate.
8
、
9
8
(
yellow
)、
9
(
green
)
Transfer(start
machine
motion)
Output
Normally open. Dry contact
closure when the arctransfers.
120 VAC/1 A maximum at the
machine interface relayor
switching device (supplied by
the customer).
13
、
14
13
(
blue
)、
14
(
white
)
Ground
Ground
Voltagedivid
er
Output
CUT: Divided arc signal of
20:1,30:1, 40:1, 50:1 (provides a
maximum of 18 V).
6
(
+
)、
7
(
-
)
6
(
red
)、
7
(
black
)
Setting the five-position voltage divider on the CUT
The factory presets the voltage divider to 20:1. To change the voltage divider to a different setting:
1. Turn OFF the power supply and disconnect the power cord.
2. Remove the power supply cover.