7
XSH Block Diagram
XSH-xxD models:
Protection
Protection
Protection
Protection
Optical
Isolation
Optical
Isolation
Optical
Isolation
Optical
Isolation
Control Logic
Protection
Receiver
Out Port 4
Out Port 3
Out Port 2
Out Port 1
In Port
Line
Termination
Transmitter
Transmitter
Transmitter
Transmitter
XSH-xxR models:
Protection
Protection
Protection
Protection
Tranceiver
Tranceiver
Tranceiver
Tranceiver
Optical
Isolation
Optical
Isolation
Optical
Isolation
Optical
Isolation
Control Logic
Protection
Teanceiver
Out Port 4
Out Port 3
Out Port 2
Out Port 1
In Port
Line
Termination
Mains Connection
The user must supply a suitable power cable. The user must then either hard-
wire the power cable to the building’s
electrical installation, providing an easily accessible power on/off switch close to the device, or install on the power
cable a grounding-type (earthed) mains plug that is suitable for the local power outlets, following the power plug
manufacturer’s instructions. Consult a qualified electrician
, if you have any doubts about proper installation.
A blue
Neutrik powerCON NAC3FCA
cable mount connector must be used to supply power at the XSH hybrid splitter
power input socket.
Warning! For protection from dangerous electric shock, the device must be grounded (earthed). The
local AC power source must have both overload and ground-fault (earth fault) protection.
Important! Only insert or remove a live Neutrik powerCON connector to apply or cut power in an
emergency, as doing so may cause arcing at the terminals that will damage the connectors.
Power Outlets
Warning! The total current load of all devices connected to AC mains power outlets of the XSH hybrid
splitter power must not exceed 19.8 amps.
• A p
ower cable that meets the requirements specified on safety instructions of this manual must be used to
connect the XSH Hybrid Splitter to AC mains power and to connect other devices to the power outlets.
• A light
-grey Neutrik powerCON NAC3FCB cable-mount connector must be used to draw AC mains power from the
XSH Hybrid Splitter’s power outlets.
• No matter what the AC mains power voltage is, the current draw of all the devices that draw AC mains power from
the power outlets of an XHS hybrid splitter must not exceed a total of 19.8 amps.
DMX Connections
Depending on the version, the XSH is equipped with 5-pin or 3-pin XLRs.
Pin
Connection
Содержание XSH
Страница 1: ...XSH Hybrid Splitter Booster User Manual...
Страница 2: ...2 UM XSH D0 LEN V01 02 DOCX 28 M r 2019...