MAINTENANCE GUIDE
5.1
To keep your sprayer in optimal condition, keep the following parts always greased: shut-off O rings, Piston sleeve, Pump tube O rings,
Plunger O rings, Nozzle O ring.
Wash the sprayer inside and outside with fresh water, to be able to handle it without contamination risk.
It is recommended to replace all wear parts when performing a repair job:
- Piston sleeve, - Shut-off O rings, - Pump tube O rings, - Plunger O rings,
- Nozzle O ring - Nozzle gasket
NOTE:
Instructions for compression sprayers:
1.-
Change the wear parts in the pump tube, shut-off, spray lance and nozzle if your sprayer is leaking or as preventive maintenance.
2.-
Unscrew the nut between spray lance and shut-off.
3.-
Change gasket located between nut and shut-off.
4.-
The shut-off is comprised by several pieces, remove the lower plug and replace gasket, remove plunger and replace the two o-rings and gasket. Lubricate
before assembly.
5.-
Unscrew the nozzle and replace O-ring and gasket, lubricate.
6.-
Remove the pump tube from the tank and replace O ring located in the upper part, lubricate before assembling.
7.-
Remove screws of the pump tube, remove handle, in the lower part replace and lubricate the the piston sleeve.
Remove the antenna from the lower end of the pump tube and replace the O ring.
To lubricate all parts; Use
silicone-based grease.
NOTE:
ATTENTION
LUBRICATE THE PUMP TUBE
BEFORE ASSEMBLING
4
COMMON PROBLEMS, POSSIBLE CAUSES & SOLUTIONS
6.
PROBLEM
The piston does not slide easily and there is noise
between the pump tube and the piston.
CAUSE
SOLUTION
There is no lubrication between the pump
tube and the piston sleeve.
Check the piston sleeve. If it is worn-down
replace it and grease it, if not just grease
the edges.
The pump system leaks.
The antenna does not seal correctly in
the seat of the pump tube.
Check the antenna and if necessary replace
the seal. Lubricate before reassembling.
Shut-off leaks after releasing the handle.
The O rings of the shut-off plunger are
worn-down or swollen.
Replace and grease the new O rings and
plunger
The sprayer is pressurized but there is no flow when
pressing the shut-off handle.
The pump tube is not tight enough.
Loosen the hose clamp and check if the hose
or the tank outlet are clogged and if so,
proceed to unclog them with pressurized air
or water
Although the sprayer is being pumped vigorously it does
not build pressure.
The hose is clogged.
Tighten the tube and grease the O ring.
2
3
5
6
7
7
4