Page 12
3481.560.02
Version 1.2
The Repeat false start signal can be adjusted from 1x to 5x . Select False Start Setup to OFF
if false signal is not used.
Power ON sequence
Action on
STV
Sequence of LEDs on
STV
Sequence of LEDs on
Start & Microphone unit
Sequence of LEDs on
1
Switch ON the unit by
pressing the
key
during 5 seconds.
During the 5 seconds of
switching on, the LED ON
(green) lights up briefly
and the backlight of the
display lights up.
During the 5 seconds of
switching on, the SPEAK
button (red) flashes and then
turns off.
The red LED flashes.
2 Release the key
after 5 seconds.
The 2 LEDs ON (green) and
LOW BAT (red) light up
alternately.
3
The LED ON (green) stays
on.
The 4 LEDs light up one after
the other and then turn off
one after the other.
4
The SWISS TIMING logo
appears on the display.
The 3 LEDs LOW BAT (red),
READY 1 and 2 (green) light up
one after the other for a short
time and then turn off one
after
the
other.
The SPEAK buttons (red) and
START (green) flash twice at
the same time.
5
The WAITING READY
message appears on the
display.
The SPEAK button (red) lights
up.
Audio levels
It is possible to adjust 5 audio levels (without going through the Main Menu):
Speaker Int.
Level of internal loudspeaker
Speaker Ext.
Level of external loudspeakers
Headset
Level of
headset
Line Out
Level of LINE OUT
Microphone
Level of microphone (SMU unit or Headset micro)
Battery level
Battery is fully charged.
Battery is half charged.
Battery is empty; connect the charger as soon as possible.
Red LED (LOW BATT) blinking to notify low battery.
Battery is empty, connect the charger urgently.