PARTS AND ACCESSORIES 

 
EYEPIECE REPLACEMENTS 
MA10510      W10XD, 18mm Eyepiece 
MA10511      W10XD, 18mm Eyepiece with Pointmaster 
 
OBJECTIVE REPLACEMENTS 
MA10071F    4XD Achromat Objective       
MA10072      10XD Achromat Objective       
MA10073S    40XRD Achromat Objective       
MA10074      100XRD Achromat Objective       
 
MISC. ACCESSORIES 
MA268          Stage Clips (pair) 
MA533          Dust Cover 
MA12005      High-drive Mechanical Stage 
MA12006      Low-drive co-axial Mechanical Stage 
MA15383      Cord Holder (pair) 
MA2202F      5W Fluorescent Bulb 
MA2215        .06 W LED replacement lamp 

 

CARE AND CLEANING 

 

The M3500 Series microscope is designed to function with minimal 
maintenance, but certain components should be cleaned frequently to 
ensure ease of viewing. The power switch should also be turned off or 
unplugged when the microscope is not in use. 
 

CLEANING

 – The front lens of the objectives (particularly the 40XRD and 

100XRD should be cleaned after use. First brush with a soft, camel hair 
brush or blown off with clean, oil free air to remove dust particles. Then 
wipe gently with a soft lens tissue, moistened with optical cleaner 
(eyeglass or camera lens) or clean water. Immediately dry with a clean 
lens paper. 

 
CAUTION

 - Objectives should never be disassembled by the user. If 

repairs or internal cleaning should be necessary, this should only be done 
by qualified, authorized microscope technician. The eyepiece(s) may be 
cleaned in the same manner as the objectives, except in most cases 
optical cleaner will not be required. In most instances breathing on the 
eyepiece to moisten the lens and wiping dry with a clean lens tissue is 
sufficient to clean the surface. Lenses should never be wiped while dry 
as this will scratch or otherwise mar the surface of the glass. 

Содержание M3500 SERIES

Страница 1: ...CROSCOPE The Swift M3500 Series microscope is considered to be the most Student proof microscope on the market It is an instrument of optical and mechanical precision and will perform satisfactorily w...

Страница 2: ...age drift CONDENSER the condenser is mounted in the stage and it is used in conjunction with the iris diaphragm The function of the condenser is to provide full illumination to the specimen plane and...

Страница 3: ...ide in place allowing the user to move the slide on any x y axis through the manipulation of two control knobs or a co axial control mechanism NOSEPIECE the revolving turret that holds the objective l...

Страница 4: ...COVER GLASS Thin glass cut in circles rectangles or squares for covering the specimen usually a thickness of 0 15 to 0 I7mm The majority of specimens should be protected by a cover glass and must be c...

Страница 5: ...esolving power is directly proportional to the numerical aperture of the optical system WORKING DISTANCE the distance from the lens of the objective to the cover slip on the slide when the specimen is...

Страница 6: ...ification of 400X or lower However at a magnification of 1 000X and above refraction becomes problematic This problem is reduced significantly by placing a thin layer of very clear viscous oil between...

Страница 7: ...100XRD objective requires an iris diaphragm for brightfield oil immersion microscopy HOW TO USE THE POINTMASTER EYEPIECE RETICLE Swift s patented POINTMASTER eyepiece reticle which is installed in the...

Страница 8: ...ware must first be installed on a computer The minimum computer requirements to use the camera is having an available USB 2 0 port Windows XP Vista or Mac OS X operating system installed on the comput...

Страница 9: ...e microscope is not in use CLEANING The front lens of the objectives particularly the 40XRD and 100XRD should be cleaned after use First brush with a soft camel hair brush or blown off with clean oil...

Страница 10: ...ay corrode your microscope Also be sure that the objectives are placed in the lowest possible position and the rotating head is turned inward and not protruding from the base Microscopes with mechanic...

Страница 11: ...s electrical cord from the electrical socket and remove any slides on the stage Use the small allen wrench 09mm that was included with the microscope to loosen the set screws that hold the black illu...

Страница 12: ...e enough Slowly open the diaphragm to increase the size of the opening allowing for additional illumination E PROBLEM Once the specimen is in focus it moves out of focus CORRECTION Gravity is causing...

Страница 13: ......

Отзывы: