14
FB160 / FB170 / FB175 / FB235 / FB255 / FB265
3
2
..
.
1
4
P
A
T
M
D
ok
: 101497C-
GB 2126
Measurement of hydraulic pressure at direction change
The hydraulic pressure at direction change to be measured is necessary to remove the cover plate at the
rear of the handle.
The hydraulic pressure when direction changes must be between 20-22 bar and with a hydraulic meter
that is to be connected to the valve assembly as shown below. The measuring point is factory-locked.
To be able to measure this obstruction, it must be released and the connector corresponding to the
measuring instrument must be bolted there. A measuring instrument and connector can be ordered from
Swepac.
Hydraulic system
1) Hidraulic pump changeover
2) Pressure regualting valve 20 BAR
3) Hidraulic cylinder Forward/Backward
4) Hand control valve
VIBRATIONSELEMNT
TANK
VENTIL