Swegon reserves the right to alter specifications.
2 www.swegon.com/casa
R85.190814
Instructions for installing the reheating cassette
Make sure th
at the cables are not in con-
tact with the heating element of the reheating
cassette. Bundle them together with bundling
straps, if needed.
11. Reinstall the rotor package back to its position.
12. Connect the quick-fit connector of the rotor.
13. Make sure that the power supply cable of the rotor pack-
age is not in contact with the surface of the rotor.
14. Reinstall the extract air filter back to its position.
15. Reinstall the protective plate back to its position.
16. Reinstall the access door back to its position.
The packaging contains the following items
• 2 screws
• Reheating cassette
• 2 small bundling straps
Tools required for installation
• Crosshead screw driver
Installation instructions
1. Unfasten the access door by removing the dummy plugs
and open the door fasteners.
2. Unscrew the screws and remove the protective plate inside
the ventilation unit.
3. Withdraw the extract air filter.
4. Disconnect the quick-fit connector of the rotor.
5. Withdraw the rotor package.
6. Lift the electric cables in the supply air section.
7. Place the reheating cassette at its position in the supply air
section below the fan. Push it into position from below as
shown in the image.
8. Fasten the reheating cassette to the frame plate between
the rotor package and the supply air section. Use 2 screws
(supplied) inserting them from below the frame plate.
9. Connect the quick-fit connector of the reheating cassette.
10. Place the cables in their original positions.
2.
3.
5.
4.