Synthetic oil HAB - Alkylbenzene type ex. EXXON ZERICE S, about 30 gr.
l
l
PVC pipe to insulate hole in the wall, external diameter 50 mm. of minimum length as for thickness wall.
POWER SUPPLY 220 / 240V ~ 50 Hz
(TO BE CONTINUED AT PAGE 3)
GENERAL PRECAUTION
l
l
Check that the voltage and frequency of the power supply
match those required by the system.
l
l
Check the possibility to have the power line to the indoor unit
(
ELECTRIC CABLE LENGTH 3 m
).
l
l
Install a double - pole switch, protected by 10 A fuses of the
delayed type, upstream the electricity wall socket.
l
l
Make sure that the electrical installation is suitable to supply
continuosly current necessary for the air conditioner in addition
to that already used by other electric appliances (white goods,
lighting). See the max electric imput indicated on the name plate
positioned on the air conditioner.
l
l
Before connecting the air conditioner to a power socket,
make sure that the socket is provided with an earth
connection in compliance with local codes.
l
l
Phillips head screw driver
l
l
Tape measure
l
l
Level
l
l
Hammer drill
l
l
Hole saw or key hole saw ø 50
l
l
19 mm
wrench
l
l
21 mm wrench
l
l
24 mm wrench
l
l
Hammer
l
l
Hacksaw
l
l
Core bits 10 mm diameter drill bit.
INSTALLATION SITE SELECTION
TOOLS REQUIRED FOR INSTALLATION (NOT SUPPLIED)
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
INDOOR UNIT
AVOID:
l
l
Positioning the indoor unit into rooms where it could be sprinkled
with water (i.e. laundries).
l
l
To install in areas where leakage of
flammable gas or large amount of mist may be expected humidity
location.
l
l
Direct sunlight or near by heat source that may affect
performance of the unit.
l
l
Installing unit behind curtains or
furniture that obstruct air circulation.
DO:
l
l
Choose a position which allows proper ventilation in the room.
l
l
Verify respect of the minimum recommended maintenance
space.
OUTDOOR UNIT
AVOID:
l
l
Direct sunlight or area where hot air from exhaust fans investing
the unit.
DO:
l
l
Choose a place as cool as possible and well ventilated.
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
FIGURE NR°
REMOTE
UNIT CONTROL
1
RAWL PLUG S X 5
2
SCREW 4,2x32
2
WASHER
2
PLASTIC PLUG
(MALE AND
2 + 2
FEMALE)
RAWL PLUG 2/3
S X 10
SCREW 7x65
2/3
WASHER
2/3
OUTDOOR UNIT
BASKET OR
1
SUPPORT
CONNECTION EXTENSION KITS -
LENGHT OF 2 OR 4 m
ACCESSORY SUPPLIED ON REQUEST
PARTI FIGURA
N°
EXTENSION KIT
FOR CONNEC-
1
TION TUBE
CONNECTIONS
1
PLASTIC BOX
RAWL PLUG
3
TAPPING SCREW
3
ø 3,5 x 45
CLAMP
2
EG
THE EXTENSION KITS ARE SUPPLIED PRECHARGED
NARROW TUBE
LARGE TUBE
OUTSIDE DIA.
OUTSIDE DIA.
6,35 mm
7,93 mm
Before the installation, verify that they are fit for the unit.
C