background image

 

11

 

6.2.2 Control – DMX 512 & manual on / off: 

 

If controlled with DMX, the machine uses one channel only, and reads all channels between 
001 and 512. The machine is ON at DMX level 77 (approx. 30%). XLR pinout:  

Pin 1 = gnd / sleeve, pin 2 = signal  -  , pin 3 = signal  + 

 
ON / OFF can be controlled with DMX or manually.  
 
There are only two ways to control an Ultimate 2000 DMX:  
1.  Manually by pressing OK button for ON, press again for OFF, or:  
2.  via DMX 512. 

 

Control with DMX signal only: 
 

  Connect a DMX cable to the male XLR connector. The DMX cable is linked to a standard 

DMX 512 source (e.g. a light desk). 

 

  Set mains switch to “1”. 

The display indicates the last stored address, or “OFF” if the last 

operation mode was manual.

 

 

  Select a DMX address between 001 and 512 (the machine uses one channel only): Use 

the up/down keys to select address (the display flashes while the new address is being 
selected). 

Tip: Press and hold “up” or “down” key for faster count.

 

 

  Press “OK” to store the selected address. 

The display will now stop flashing, to confirm the 

address is stored.      

 

  When the level of the selected DMX address is 77 or more, the machine is on. When the 

level is 76 or less, the machine is off. The red “operation” LED indicates the machine is 
switched on by the DMX electronics. 

 

  If the DMX source is manually controlled with potentiometers make sure the potentiometer 

is not adjusted only around level 77. It can make the machine go on and off repeatedly. 
The output cannot be controlled with the DMX level, only through the operating

 

intervals. 

The best way to control the machine without the risk of an unwanted start or stop (and risk 
of damage to compressor motor), is to set the level at 0 (0%) for off, and 255 (100%) for 
on. 

 

Tip: The last selected address will be stored in the processor´s memory when the machine is 
switched off and/or mains voltage is disconnected. The address is set as default next time the 
machine is switched on.  
In an application where the machine is used with the same address every time (e.g. on tour or 
in permanent installations), it is not necessary programme again at power on, as the last 
selected address is pre-set as default. 
If, for any reason, a different address is to be used temporarily: Set the temporary address, 
but do NOT press “OK” (the temporary address will flash in the display). The machine will 
respond to the temporary address until mains power is switched off. Next time it is switched 
on, the usual, favourite address will be set as default.       

 

Manual control without DMX: 
 

  Select an address below 1 or above 512 (the display indicates “OFF”). 

 

 Press “OK” button to start and stop (the display indicates “On”. The red “operation” LED 

indicates the machine is on.   

 

Remote control from external power sources: 
Ultimate 2000 DMX cannot be controlled from external switch or relay units. Use the 
integrated DMX control, connected to a DMX light desk, or manual control only. When 
used in “manual” mode; for safety reasons, electronics will always start up in “OFF” 
mode if mains supply is disconnected and re-connected again. Machine will not start 
automatically, “OK” button must be pressed.  

 

Содержание Ultimate 2000DMX

Страница 1: ...Swefog Ultimate 2000DMX 20 202 240 Ultimate 2000 DMX 230V 50Hz Rev 2 2012 12 02 OWNER S MANUAL ...

Страница 2: ...avant l assemblage le montage et de faire fonctionner cet équipement WICHTIG Lesen Sie alle Warnungen sorgfältig bevor Sie das Gerät zusammenbauen installieren und benutzen IMPORTANTE Por favor lea todas las precaucionas y las advertencias antes de ensamblar montar y operar este equipo IMPORTANTI Leggere tutti gli avvertenti prima di montare e usare questo apparecchio ...

Страница 3: ...inlet filter mats on machine housing 9 6 1 2 Ergonomic AluGrip handle 9 6 2 Control panel display 10 6 2 1 Normal operation 10 6 2 2 Control DMX 512 manual on off 11 6 3 Fluids 12 7 SERVICE MAINTENANCE REPAIR 13 8 SPECIFICATIONS 13 SWEFOG WORLDWIDE WARRANTY 14 Manufactured by S W E F O G T E C H N O L O G Y G R O U P AB INDUSTRIVÄGEN 15 SE 682 33 FILIPSTAD SWEDEN Tel 46 590 122 50 e mail info swef...

Страница 4: ...ll find the following symbols CAUTION This symbol appears adjacent to caution messages Not heeding these messages could result in minor personal injury and or damage to equipment QUICK SETUP GUIDE 1 Read chapter 3 SAFETY PRECAUTIONS 2 Place machine on a level surface 3 Fill Swefog Ultimate haze fluid in the tank fill slowly and do NOT exceed the max level indicator 4 Connect to a mains outlet with...

Страница 5: ...tenance can be downloaded from www swefog com Refer all service and repair work to qualified personnel This manual and updates can also be downloaded as PDF files from www swefog com 2 UNPACKING Swefog Ultimate 2000 DMX package contains One machine One manual Please note no mains cable is included and no fluid Save the box and packing material for future use If the machine needs to be transported ...

Страница 6: ...als when it is ON If mains voltage input is regulated through a dimmer switch the compressor and other electric components will be damaged Service internal parts ONLY if you have the know how and experience to perform the service correctly If not please contact a Swefog service centre or the manufacturer NOTE Incorrect service and or use of non original spare parts will void the warranty NEVER cha...

Страница 7: ...only Use only Swefog Ultimate fluid in this machine Use responsible concentrations of haze to create atmospheric effects Not for residential use Must be handled by qualified personnel at all times According to a report commissioned by Actors Equity Association and the League of American Theatres and Producers mineral oil should be used in such a manner that an Actors exposure does not exceed a pea...

Страница 8: ...r electrical data 3 Fluid fill 4 Haze outlet 5 Fluid level indicator 6 Left side air inlet 7 Front side air inlet 8 Heavy duty rubber feet 9 Internal fan air inlet filter holder screws release both screws when replacing the filter mat 10 Internal fan air inlet filter frame 11 Control panel connectors ...

Страница 9: ...t left right sides of machine housing the second mat covers the rear fan inlet Replacement of compressor s air inlet filter cartridge Cleaning of the compressed air filter cartridge Cleaning of the nozzle unit only necessary if haze output is low Cleaning or replacement of haze fluid filter If necessary empty and clean the fluid tank NOTE The filter mats are made with a special material that withs...

Страница 10: ...VER fill fluid while machine is operating The machine is continuously cooled by several fans and an intercooler and can operate without interruption as long as there is mains power and fluid supply Operating the machine with an empty fluid tank does not damage the machine Connect a mains cable to a suitable mains outlet for 230V min 5 Amps capacity NOTE Due to the high starting current the machine...

Страница 11: ...t be controlled with the DMX level only through the operating intervals The best way to control the machine without the risk of an unwanted start or stop and risk of damage to compressor motor is to set the level at 0 0 for off and 255 100 for on Tip The last selected address will be stored in the processor s memory when the machine is switched off and or mains voltage is disconnected The address ...

Страница 12: ... The oils used during the manufacturing process are also filtered several times to ensure an extremely clean fluid Swefog Ultimate fluids are of medical grade which is the finest oil quality available Medical grade oils which is a quality grade far better than food grade or technical grade is also used in manufacturing of medicals and similar processes with extremely high demands on purity cleanli...

Страница 13: ...lified technical personnel or contact a preferred Swefog dealer Preferred dealers have qualified service technicians and will be able to perform most service works 8 SPECIFICATIONS Type Cracker haze generator pneumatic Fluid type Mineral oil based Operation Continuous Fluid consumption Approximately 0 05 litre 0 01 US gal per hour Fluid reservoir capacity 2 5 litre 0 66 US gal Cracker nozzle type ...

Страница 14: ...xtures or other spare parts shipped in non factory shipping cartons and packing materials Limited Warranty Unless otherwise stated Swefog products are covered by a two year parts and labour limited warranty Guarantee will be invalid if the Swefog machines have been used with non original fluids It is the owner s responsibility to furnish receipts or invoices for verification of purchase date and d...

Отзывы: