Assembly Reference Data 

 

Item 

Component Name 

Kit Type(s) 

Torque 

lbf·ft (N·m) 

Recommended Lubrication 
(included in kit per Table 1) 

Body 

N/A 

 

 

Diaphragm O-ring 

B1, B2, C1 

 

 

Poppet spring 

C1, C5 

 

 

Poppet O-ring

 

A1, A2, B1, B2, C1 

 

Lubricate 

Poppet 

A1, A2, B1, C1 

 

 

Seat O-ring 

A1, B1, B2, C1 

 

 

Seat 

A1, B1, C1 

 

 

Seat retainer 

C1 

11 (15) 

Lubricate threads 

Diaphragm screw

 

C1 

3.7 (5) 

Lubricate threads 

10 

Diaphragm 

B1, B2, C1, C3 

 

 

11 

Bottom spring guide 

C1 

 

 

12 

Washer

 

C1 

 

 

13 

Hex nut

 

C1 

3.7 (5) 

 

14 

Clamp ring 

C1 

 

 

15 

Set spring 

C1, C4 

 

 

16 

Spring guide 

C1 

 

Lubricate central recess 

17 

Ball

 

C1 

 

Lubricate 

18 

Spring housing 

N/A 

37 (50) 

Lubricate threads 

19 

C-ring 

D1 

 

 

20 

Knob assembly 

D1 

 

Lubricate threads 

21 

Spring housing cover

 

N/A 

 

Adhesive on external threads 

22 

Lock nut 

D1 

 

 

23 

Anti-tamper set screw 

D1 

 

Lubricate threads 

24 

Anti-tamper cover 

D1 

 

Lubricate threads 

25 

Anti-tamper cover O-
ring

 

B1, B2, C1, D1 

 

 

  PRS8 series only 

  PRS4 series, anti-tamper option only 

Table 2 

 
For more information on RHPS series maintenance kits, refer to the 

Sanitary Pressure Regulators, RHPS 

Series

 catalog, MS-02-436. 

Содержание PRS4

Страница 1: ...PRS4 and PRS8 Pressure Reducing Regulator User Manual Read the complete manual before installing and using the regulator...

Страница 2: ...dia should be free of excessive moisture to prevent icing at high flow Always wear the appropriate protective clothing including safety glasses gloves etc if required Follow the applicable safety and...

Страница 3: ...Operation 6 Points of Attention Before Operation 6 Adjusting the Set Pressure 6 Maintenance 7 Required Tools for Maintenance 7 Points of Attention Before Removal from the System 8 Removal from the Sys...

Страница 4: ...oduct failure Standard Features Threaded construction Stainless steel as standard Fully serviceable Diaphragm sensing Bottom mounting Additional Options The regulator is available with the following o...

Страница 5: ...s materials of construction and the system media Installation Verify that the regulator its connections and any accessories are undamaged Verify that the regulator and any accessories are suitable for...

Страница 6: ...sure may result in a fall of the outlet pressure This is usually referred to as inlet dependency or Supply Pressure Effect SPE This phenomenon does not indicate a problem with the regulator Adjusting...

Страница 7: ...ng or normal operation Swagelok recommends having maintenance kits readily available on site The need for maintenance kits is particularly important during the commissioning phase of a system installa...

Страница 8: ...or toxic If required take the necessary safety precautions to ensure a safe workspace and your personal safety CAUTION The product can be hot or cold depending on the environmental temperature and the...

Страница 9: ...ide C1 12 Washer C1 13 Hex nut C1 3 7 5 14 Clamp ring C1 15 Set spring C1 C4 16 Spring guide C1 Lubricate central recess 17 Ball C1 Lubricate 18 Spring housing N A 37 50 Lubricate threads 19 C ring D1...

Страница 10: ...10 PRS4 Series Exploded View Fig 1...

Страница 11: ...11 PRS4 Series Section View Fig 2...

Страница 12: ...12 PRS8 Series Exploded View Fig 3...

Страница 13: ...13 PRS8 Series Section View Fig 4...

Страница 14: ...e 11 6a PRS4 series Remove the seat retainer 8 using the seat retainer insertion tool Remove the seat 7 seat O ring 6 poppet 5 and poppet spring 3 from the body 1 6b PRS8 series Remove the seat retain...

Страница 15: ...guide 11 12 Lightly lubricate the spring housing threads 18 and screw it onto the body 1 Torque to 37 lbf ft 50 N m PRS8 Series 1 Secure the body 1 in a vise 2 Fit the poppet O ring 4 onto the poppet...

Страница 16: ...ly 14 5 psig 1 bar on the regulator and close the downstream shutoff valve 4 Monitor the outlet pressure An increase in pressure over time indicates a seat leak 5 Repeat the procedure with the highest...

Страница 17: ...er than the desired set pressure The outlet pressure rises too much when going from a dynamic to a static situation There is too much flow in the dynamic situation A larger regulator or parallel regul...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...e Swagelok Limited Lifetime Warranty For a copy visit swagelok com or contact your authorized Swagelok representative Swagelok Snoop TM Swagelok Company Loctite TM Henkel Corp Krytox TM The Chemours C...

Отзывы: