Swagelok PRS4 Скачать руководство пользователя страница 17

17 

 

Troubleshooting 

 
Symptom 

Cause 

Remedy 

The outlet pressure creeps up, 
without adjusting the spring. 

A damaged poppet and/or 
seat. 

Replace the poppet and/or seat. 

Leakage between the body and 
the spring housing or through the 
spring housing weep hole. 

A damaged diaphragm or O-
ring. 

Replace the diaphragm or O-ring. 

Insufficient torque on the 
spring housing. 

Tighten the spring housing per Table 2. 

Controlled pressure drops off 
sharply even when the flow is 
within regulator capabilities. 

The system filter element is 
clogged. 

Replace the system filter. 

The required outlet pressure 
cannot be reached. 

The inlet pressure to the 
regulator is not high enough. 

Ensure that the inlet pressure to the 
regulator is equal to or greater than the 
desired set pressure. 

The outlet pressure rises too 
much when going from a dynamic 
to a static situation. 

There is too much flow in the 
dynamic situation. 

A larger regulator or parallel regulator is 
required. 
Review application flow capacity and 
contact your local authorized sales and 
service center. 

The outlet pressure does not drop 
when the knob is adjusted 
counterclockwise. 

The regulator is non-venting. 

A shutoff valve in the outlet line must be 
opened to reduce the outlet pressure. 

The outlet pressure has changed 
without adjusting the handle. 

Changes to the inlet pressure 
may result in changes to the 
outlet pressure. 

Maintain a constant inlet pressure to the 
regulator. See “

Points of Attention 

Before Operation

” about 

dependency

Changes to the flow may result 
in changes to the outlet 
pressure. 

Maintain a constant flow through the 
regulator. See “

Points of Attention 

Before Operation

” about 

droop

 

Table 3 

 

Содержание PRS4

Страница 1: ...PRS4 and PRS8 Pressure Reducing Regulator User Manual Read the complete manual before installing and using the regulator...

Страница 2: ...dia should be free of excessive moisture to prevent icing at high flow Always wear the appropriate protective clothing including safety glasses gloves etc if required Follow the applicable safety and...

Страница 3: ...Operation 6 Points of Attention Before Operation 6 Adjusting the Set Pressure 6 Maintenance 7 Required Tools for Maintenance 7 Points of Attention Before Removal from the System 8 Removal from the Sys...

Страница 4: ...oduct failure Standard Features Threaded construction Stainless steel as standard Fully serviceable Diaphragm sensing Bottom mounting Additional Options The regulator is available with the following o...

Страница 5: ...s materials of construction and the system media Installation Verify that the regulator its connections and any accessories are undamaged Verify that the regulator and any accessories are suitable for...

Страница 6: ...sure may result in a fall of the outlet pressure This is usually referred to as inlet dependency or Supply Pressure Effect SPE This phenomenon does not indicate a problem with the regulator Adjusting...

Страница 7: ...ng or normal operation Swagelok recommends having maintenance kits readily available on site The need for maintenance kits is particularly important during the commissioning phase of a system installa...

Страница 8: ...or toxic If required take the necessary safety precautions to ensure a safe workspace and your personal safety CAUTION The product can be hot or cold depending on the environmental temperature and the...

Страница 9: ...ide C1 12 Washer C1 13 Hex nut C1 3 7 5 14 Clamp ring C1 15 Set spring C1 C4 16 Spring guide C1 Lubricate central recess 17 Ball C1 Lubricate 18 Spring housing N A 37 50 Lubricate threads 19 C ring D1...

Страница 10: ...10 PRS4 Series Exploded View Fig 1...

Страница 11: ...11 PRS4 Series Section View Fig 2...

Страница 12: ...12 PRS8 Series Exploded View Fig 3...

Страница 13: ...13 PRS8 Series Section View Fig 4...

Страница 14: ...e 11 6a PRS4 series Remove the seat retainer 8 using the seat retainer insertion tool Remove the seat 7 seat O ring 6 poppet 5 and poppet spring 3 from the body 1 6b PRS8 series Remove the seat retain...

Страница 15: ...guide 11 12 Lightly lubricate the spring housing threads 18 and screw it onto the body 1 Torque to 37 lbf ft 50 N m PRS8 Series 1 Secure the body 1 in a vise 2 Fit the poppet O ring 4 onto the poppet...

Страница 16: ...ly 14 5 psig 1 bar on the regulator and close the downstream shutoff valve 4 Monitor the outlet pressure An increase in pressure over time indicates a seat leak 5 Repeat the procedure with the highest...

Страница 17: ...er than the desired set pressure The outlet pressure rises too much when going from a dynamic to a static situation There is too much flow in the dynamic situation A larger regulator or parallel regul...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...e Swagelok Limited Lifetime Warranty For a copy visit swagelok com or contact your authorized Swagelok representative Swagelok Snoop TM Swagelok Company Loctite TM Henkel Corp Krytox TM The Chemours C...

Отзывы: