5
Installation
CAUTION
Do not use the regulator as a shutoff device. A level of leakage across the regulator seat can
occur during normal operation.
Points of Attention Before Installation
This regulator can be equipped with a variety of different options. Before installing the regulator you should
fully understand the functions of the supplied options and the suitability of your particular regulator for the
intended application.
-
The preferred mounting position of the regulator is horizontal with the spring housing/dome facing
upwards per Fig 3. Alternative mounting positions may increase the risk of component wear.
-
It may be necessary to remove the regulator from the system during maintenance or service. Ensure that
this is possible.
-
The regulator is suitable for gases or liquids. Ensure compatibility between the regulator
’s materials of
construction and the system media.
Installation
-
Verify that the regulator, its connections, and any accessories are undamaged.
-
Verify that the regulator and any accessories are suitable for the system operating pressure and
temperature and have suitable connections.
-
At the time of delivery any gauge ports may be plugged with blind fittings. Remove these and connect
gauges if desired.
-
If inlet/outlet fittings are being used, assemble them to the regulator,
per the manufacturer’s instructions,
prior to installing the regulator in the system.
CAUTION
Ensure all upstream tubing/pipework is clean and free from debris. Any swarf, lint, wire, etc. may
damage the regulator, resulting in a seat leak.
-
Verify the flow direction of the system and mount the regulator accordingly.
-
This regulator can be bottom mounted or panel mounted. The panel mounting kit can be ordered
separately.
-
Securely make the appropriate connections to the regulator in accordance with the procedures
recommended by the connection manufacturer.
-
Ensure that the tubing/pipework and the regulator are adequately supported and that there is no stress on
the connections.
-
Upstream and downstream shutoff valves should be installed in the system to facilitate servicing,
maintenance, and troubleshooting of the regulator.