height (full voltage, shunt resistor might be necessary) with the
adjusted duty cycle
-
Use a PWM frequency high enough not to interfere with your
timings (here: 1000 Hz)
Scenario values
Interval 0 (RED)
Interval 1 (GREEN)
Interval 2 (BLUE)
Interval 3 (WHITE)
Sequencer Interval
1000 ms
1000 ms
1000 ms
1000 ms
Seq pulse A start
0 ms
0 ms
100 ms
0 ms
Seq pulse A stop
100 ms
300 ms
300 ms
100 ms
Seq pulse B start
0 ms
100 ms
200 ms
0 ms
Seq pulse B stop
100 ms
200 ms
300 ms
33 ms
PWM Frequency f
1000 Hz
1000 Hz
1000 Hz
1000 Hz
PWM change 0 (RED)
100%
0%
0%
100%
PWM change 1 (GREEN)
0%
70%
0%
70%
PWM change 2 (BLUE)
0%
0%
80%
80%
PWM change 3
-
-
-
-