USER’S MANUAL
1. INTRODUCTION
The UPS are an extremely reliable standby Uninterruptible Power System designed to keep computers and peripheral devices such as com-
puter, storage subsystems, fax machines, modems, etc performing from the utility power failure which could result in damage of data.
In the event of utility failure, the UPS supplies power to your equipment derived from a battery within the UPS and provides visual and audi-
ble indicators which alert you to utility line failures, therefore, the user has ample time to save file and close operations.
2. SAFETY INSTRUCTIONS
Although your UPS has been designed and manufacturer to assure personal safety, improper use can result in electrical shock or fire.
To assure safety, please observe the following rules:
• Turn off and unplug your UPS before cleaning. Do not use liquid or aerosol cleaner.
• A dry cloth is recommended dust from the surface of your UPS.
• Do not install or operate your UPS in near water.
• Do not place UPS on an unstable cart, stand or table.
• Do not place UPS under direct sunlight or close to heat emitting source.
• Do not place UPS power cord in any area where it may get damaged by heavy objects.
• Do not connect UPS to home appliance e.g. hairdryer, fan etc.
• Do not connect UPS to Laser printer.
• If you store the UPS or UPS does not operate for a long period, recharge the battery every month by starting the UPS for 8 hours.
• Replace the battery with the same number and type of batteries as originally installed in the UPS.
• The UPS must be unplugged from the AC power source before replacing batteries (this operation require specialist).
3. PACKAGE INCLUDES
1) UPS (power cord is built-in foorm) — 1 pc
2) RS-232 cable — 1 pc
3) RJ-11 cable — 1 pc
4) PowerManager Software CD — 1 pc
5) Instruction manual — 1 pc
6) Warranty card — 1 pc
Note:
The additional software Upsilon 2000 for Vista is placed on a site http://en.www.sven.ru/
4. THE MAIN FEATURES
• Full digital microprocessor controlled
• Boost and buck AVR (Auto Voltage Regulation)
• High reloading ability
• RS-232 communication port
• Fax/Modem/Network surge suppression
• Cold start function (DC power on)
• Short Circuit and overload protection
5. STORAGE
Store at +15 to +30 °C (+59 to + 86 °F), charge the UPS battery every six months.
Store at +30 to +45 °C (+86 to +113 °F), charge the UPS battery every three months.
6. CONTROLS AND INDICATORS
6.1 FRONT PANEL
a
Main Switch
To Control on/off the UPS when Utility is normal.
To enable "DC-Start" Function when Utility fails. (To enable DC Start properly, you are
recommended to connect < 80 % output load with the UPS only.)
b
Line LED
Green LED remains standstill when Utility is normal.
c
Inverter LED
Red LED flashes every 5 seconds when Utility failure.
d
Charge LED
12
Содержание Pro+ 500
Страница 1: ...PRO 500 700...
Страница 2: ...SVEN Sven Ltd 2008 1 0 1 V 1 0 1 http www sven ru 2...
Страница 6: ...7 7 1 RS 232 7 2 a a 20 1 7 3 a 7 4 8 7 5 0 7 0 8 0 7 0 8 0 8 0 7 0 8 0 9 1 0 6 TEL FAX RS232...
Страница 7: ...7 6 7 7 RJ 11 45 10 Base T IN OUT 7 8 4 7 SVEN Power Pro 500 700...
Страница 8: ...8 9 8 1 2 3 1 2 3 1 2 3 1 2 3 1 2 1 8 2 3 5...
Страница 16: ......