background image

5. INSTALLATION

1. Connect loading to output AVR NEO R. 
2. Connect AVR to utility power 220VAC
3. Switch On the AVR. Switcher Indicator, «Overload» , «Line» will light and self-testing begin. During the self-testing 
Switcher Indicator, «Overload» , «Line» will light. When self-testing finish  «Overload» , «Line» will light out.
4. After 10 second self-testing, indicator «Overload» will go out and indicator «Line» will be lit and a voltage will be connected 
to target sockets. If indicator «Overload» after testing will not go out to maintain the stabilizer it is forbidden
5.At job of the AVR boost or buck of an entrance voltage indicator «Stabilization» will be shone
6. In case of an overload or short circuit the AVR will disconnect of a voltage. After elimination of the reason of 
an overload the stabilizer is necessary for switching on again.
7. Avoltage on an input from above 270 volt the AVR will be disconnected. Thus indicator «Overload» will be shone.

6. TROUBLESHOOTING

Situation

Check Items

Solution

The AVR does not work. 

1. Is the power switch on? 
2. Is the voltage in the utility power socket?
3. Too much loading is connected to 
the AVR.

1. Press main Switch on. 
2. Be convinced available 
an entrance voltage. 
3. Disconnect some loading. 

The indicator «overload» does not die 
away and there is no target voltage. 

1. Failure of the scheme of testing. 
2. The AVR is faulty. 
3. An entrance voltage too high. 

Switch-off and anew switch on the 
AVR. If the problem is not eliminated it 
is necessary to address in the service 
center. 

The AVR often clicks, thus indicator 
«Stabilizer» lights up. 

The entrance voltage is very instability. 

It is normal. The AVR adjusts 
a target voltage. 

The AVR has disconnected loading. 
The indicator «Overload» is shone. 

An INPUT voltage too high/low. 

When the input voltage becomes normal 
(170—270 VAC) the AVR will work. 

7. SPECIFICATIONS

Specification/model

NEO R 500 

NEO R 850

Maximum load 

500 VА/280 W 

850 VА/450 W 

Protection 

Over current, short circuit, overload, against a lightning 

Surge energy rating 

320 J 

Indicators 

LEDs indicating Output off, Normal, AVR 

Input EURO 

socket 

Output 

2 pc EURO socket 

2 pc EURO IEC 320 

Operating environment 

0—40 °C, 10—90 % Rh, non condensing 

Agency Approval 

CE, RusTest 

Input Voltage Range 

170—270 V 

Output Voltage Range 

198—238 V 

Frequency 50/60 

hz 

Weight, kg 

1.42 

1.85 

Dimension, mm 

118 х 112 х 106 

124 х 124 х 119 

Cable length, m

0.6

0.6

Notes:

1). This manual is provided «as it is», without any warranties, either express or implied. The supplier and its distributors are not 
liable for any error, correctness, accuracy and reliability of the information, either express or implied, herein contained.
2). The manufacturer and its distributor are not liable for any direct, indirect, incidental, consequential, loss of business 
profits, punitive or special damages, even if it and its suppliers have been advised of the possibility of such damages.

Durability — 5 years.

Eng

   NEO R 500/850

7

Отзывы: