Monitoring Station SV 279 PRO
36
Appendix A. SV 279 PRO Monitoring Station Technical Data
1
Nr
Parameter
Value/ Description
Physical data
1
Dimensions
SM 279 PRO
– 300 x 260 x 190 mm
SA 250
– 450 x 400 x 155 mm
2
Weight
SM 279 PRO
– ~10 kg
SA 250
– ~4 kg
4
Leakproof
classification
SM 279 PRO
– IP67 according to EN 60529 (1997) + A1
(2000)
5
Working
temperature
range
-30
C do +60
C (Ambient air temperature, without direct
sunlight).
Note: Outside this range the station will automatically switch
itself off.
Note: In charging mode the range of working temperature is:
-20
C to +50
C !
6
Storage
temperature
range
SM 279 PRO and SA 250: -40
C to +70
C
9
Working relative
humidity range
0
– 100 %RH
Power Supply
20
Internal battery
Europower EP 17-12 (12 V, 17 Ah)
21
SV 279 PRO
power
consumption
without charging
Modem is switched off:
~1,1W
Mean infrequent short transmissions: ~1,6W
Continuous transmission:
~2,1W
22
Operating time
when powered
from the internal
battery, (20
C,
17 Ah, fully
charged)
Modem is switched off:
~190h (~8d)
Mean infrequent short transmissions: ~120h (~5d)
Continuous transmission:
~90h (~4d)
23
SV 279 PRO
power
consumption
including
charging
up to 30W ±5%
1
Our Company’s policy is based upon continuous product development and innovation. Therefore, we
reserve the right to change the specifications without any prior notice whatsoever