IMPORTANT - GROUNDING METHOD 

This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It 

must be plugged into a mating grounding type receptacle in accordance with the National Electrical 
Code and applicable local codes and ordinances. If the circuit does not have a grounding type 
receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in 
accordance with the National Electrical Code and applicable local codes and ordinances. The third 
ground prong should not, under any circumstances, be cut or removed. Never use the cord, the plug or 
the appliance when they show any sign of damage. Do not use your appliance with an extension cord 
unless it has been checked and tested by a qualified electrical supplier. Improper connection of the 
grounding plug can result in risk of fire, electric shock and/or injury to persons associated with the 
appliance. Check with a qualified service representative if in doubt that the appliance is properly 
grounded. 

 

ELECTRICAL CONNECTIONS 

Before plugging the appliance into the mains socket, check that: 

● The mains power supply corresponds to the value indicated on the rating plate on   

the back of the appliance. 

● The power socket and electrical circuit are adequate for the appliance. 

● The mains socket matches the plug. If this is not the case, have the plug replaced. 

● The mains socket is adequately earthed. Failure to follow these important safety instructions absolves 

the manufacturer of all liability. 

 

Important information for correct disposal of the product in accordance with EC Directive 

2012/19/EU. 

At the end of its working life, the product must not be disposed of as 
urban waste. It must be taken to a special local authority 
differentiated waste collection centre or to a dealer providing this 
service.      Disposing of a household appliance separately avoids 
possible negative consequences for the environment and health 
deriving from inappropriate disposal and enables the constituent 
materials to be recovered to obtain significant savings in energy 
and resources. As a reminder of the need to dispose of household 
appliances separately, the product is marked with a crossed-out 
wheeled dustbin. 

 

Содержание 8.436.545.202.705

Страница 1: ...onditioner User Manual SVAN212PF SVAN212PBL Thank you for selecting our quality appliance Please be sure to read this user manual carefully before using Any question please contact the professional se...

Страница 2: ...rvices should be referred to a qualified technician Do not place the power cord or appliance near a heater radiator or other heat source It can result in the risk of electric shock or fire This unit i...

Страница 3: ...es or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with...

Страница 4: ...operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evalua...

Страница 5: ...from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing shall onl...

Страница 6: ...rigerants Annex CC 3 Compliance with national regulations 4 Storage of equipment appliances Annex CC 4 The storage of equipment should be in accordance with the manufacturer s instructions 5 Storage o...

Страница 7: ...r intrinsically safe 5 Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be availab...

Страница 8: ...corroded or are suitably protected against being so corroded 9 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspectio...

Страница 9: ...e circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use Intrinsically safe components are the only types that can be worked on while...

Страница 10: ...brazing process 12 Removal and evacuation Annex DD 9 When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important t...

Страница 11: ...nd all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is requir...

Страница 12: ...ssure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good wor...

Страница 13: ...ventilation of the housing Switching off the appliance or opening of the housing has no significant effect on the safety Nevertheless it is possible that leaking refrigerant may accumulate inside the...

Страница 14: ...cing units with flammable refrigerants Ensure sufficient ventilation at the repair place Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible...

Страница 15: ...n should guard the outlet Take special care that drained refrigerant will not float back into the building Evacuate the refrigerant circuit Purge the refrigerant circuit with nitrogen for 5 min Evacua...

Страница 16: ...nce is properly grounded ELECTRICAL CONNECTIONS Before plugging the appliance into the mains socket check that The mains power supply corresponds to the value indicated on the rating plate on the back...

Страница 17: ...ed by condensation Experts have established that the optimum environmental conditions for our well being and for the home are obtained between 40 and 60 relative humidity With very low temperatures yo...

Страница 18: ...r appliance may be slightly different Be sure all accessories are removed from the packing before use INSTALLATION INSTRUCTIONS EXHAUSTING HOT AIR In the Cool Mode the appliance must be placed close t...

Страница 19: ...slider kit has been designed to fit most standard vertical and horizontal window applications however it may be necessary for you to modify some aspects of the installation procedures for certain typ...

Страница 20: ...to minimize noise and vibration For safe and secure positioning place the unit on a smooth level floor strong enough to support the unit The unit has casters to aid placement but it should only be ro...

Страница 21: ...appear Never turn the appliance off by unplugging from the mains Always press the button then wait for a few minutes before unplugging This allows the appliance to perform a cycle of checks to verify...

Страница 22: ...on a number of times until the Heat symbol appears Select the target temperature13 27 55 81 by pressing the or button until the corresponding value is displayed Select the required fan speed by pressi...

Страница 23: ...ot need to be attached Press the button a number of times until the Fan symbol appears Select the required fan speed by pressing the button Three speeds are available High Medium Low The screen displa...

Страница 24: ...art up or shutdown this avoids wasting electricity by optimizing operating periods Programming start up Turn on the appliance choose the mode you want for example cool 24 high fan speed Turn off the a...

Страница 25: ...times until the corresponding time is displayed Wait about 5 seconds the timer will be active then Timer symbol is displayed on screen A few second after set the setting is memorized the timer indica...

Страница 26: ...vention The appliance is fitted with a frost protection device to avoid excessive formation of ice The appliance starts up again automatically when the defrosting process is completed PROBE FAILURE se...

Страница 27: ...ntrol at the receiver on the appliance The remote control must be no more than 7 meters away from the appliance without obstacles between the remote control and the receiver The remote control must be...

Страница 28: ...onment Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries Do not dispose of batteries in fire Batteries may explode or leak If the remot...

Страница 29: ...ect the required fan speed by pressing the button Four speeds are available High Medium Low Auto Water is removed from the air and collected in the tank When the tank is full the appliance shuts down...

Страница 30: ...way as for cool mode with the air exhaust hose attached to enable the moisture to be discharged outside To set this mode correctly Press the button a number of times until the Dry symbol appears The f...

Страница 31: ...l for the night as it gradually reduces operation of the appliance To set this function correctly Select the cool or heat mode as described above Press the button The appliance operates in the previou...

Страница 32: ...startup or shutdown this avoids wasting electricity by optimising operating periods Programming start up Turn on the appliance choose the mode you want for example cool 24 high fan speed Turn off the...

Страница 33: ...from direct exposure to the sun by partially closing curtains and or blinds to make the appliance much more economical to run fig 12 Never rest objects of any kind on the appliance Do not block the a...

Страница 34: ...emove the lower drain plug 4 Water will drain out and collect in the drain pan maybe not supplied 5 After the water is drained replace the lower drain plug firmly 6 Turn on the unit Continuous Drainin...

Страница 35: ...T You should clean the appliance with a slightly damp cloth then dry with a dry cloth Never wash the appliance with water It could be dangerous Never use petrol alcohol or solvents to clean the applia...

Страница 36: ...damaged and the earth system is efficient Follow the installation instructions precisely END OF SEASON OPERATIONS To empty the internal circuit completely of water remove the cap fig 32 Run off all wa...