1. INSTALLATION
12
19°-22° transom angle (small aluminum and fiberglass boats)
: Position the
shim with the tapered end up.
3. If the bracket has been temporarily fastened to the transom, remove it. Apply a
marine sealant to the threads of the three #10 x 1-1/4” self-tapping screws to pre-
vent water seeping into the transom. Screw the bracket to the hull. Do not tighten
the screws completely at this time.
4. Repeat step 1 to ensure that the angle
of the sensor is correct.
Note:
Do not position the sensor farther
into the water than necessary to avoid
increasing drag, spray, and water noise
and reducing boat speed.
5. Using the vertical adjustment space on
the bracket slots, slide the sensor up or
down to provide a projection of 3 mm (1/
8”). Tighten the screws.
How to attach the sensor to the bracket
1. If the retaining cover near the top of the
bracket is closed, open it by depressing
the latch and rotating the cover down-
ward.
2. Insert the sensor's pivot arms into the slots
near the top of the bracket.
3. Maintain pressure until the pivot arms click
into place.
4. Rotate the sensor downward until the bottom
snaps into the bracket.
5. Close the retaining cover to prevent the
accidental release of the sensor when your
boat is underway.
How to route the cable
Route the sensor cable over the transom, through a drain hole, or through a new hole
drilled in the transom above the waterline.
Never cut the cable or remote the connector; this will void the warranty. Always wear
safety goggles and a dust mask.
1. If a hole must be drilled, choose a location well above the waterline. Check for
obstructions such as trim tabs, pumps, or wiring inside the hull. Mark the location
with a pencil. Drill a hole through the transom using a 19 mm or 3/4” bit (to
accommodate the connector).
2. Route the cable over or through the transom.
Cable cover
Cable
clamp
50 mm (2")
Hull projection 3 mm (1/8")
Step 1
Step 2
Step 3
Step 4
Latch
Pivot
arm
Slot
Retaining
cover
1. INSTALLATION
13
3. On the outside of the hull secure the cable against the transom using the cable
clamps. Position a cable clamp 50 mm (2") above the bracket and mark the
mounting hole with a pencil.
4. Position the second cable clamp halfway between the first clamp and the cable
hole. Mark this mounting hole.
5. If a hole has been drilled in the transom, open the appropriate slot in the transom
cable cover. Position the cover over the cable where it enters the hull. Mark the
two mounting holes.
6. At each of the marked locations, use a 3 mm or 1/8” bit to drill a hole 10 mm
(3/8”) deep. The prevent drilling too deeply, wrap masking tape around the bit 10
mm (3/8”) from the point.
7. Apply marine sealant to the threads of the #6
u
1/2” self-tapping screw to prevent
water from seeping into the transom. If you have drilled a hole through the
transom, apply marine sealant to the space around the cable where it passes
through the transom.
8. Position the two cable clamps and fasten them in place. If used, push the cable
cover over the cable and screw it in place.
9. Route the cable to the display unit being careful not to tear the cable jacket when
passing it though the bulkhead(s) and other parts of the boat. To reduce electrical
interference, separate the sensor cable from other electrical wiring and "noise"
sources. Coil any excess cable and secure it in place with zip-ties to prevent
damage.
1.3.5
Matching box (required for 50/200-1T transducer)
The matching box (Available as an optional extra. Type: MB-1100, Code No.: 000-
041-353) is required to connect the optional 50/200-1T transducer.
*: With 10P connector cable
**: For connecting two transducers
Part
Type
Code no.
Qty
Matching Box*
MB-1100
000-041-353
1
Crimp-on Lug
FV1.25-3 (LF)
000-166-756-10
6
Cord Lock**
NC-1
000-168-230-10
1
Vinyl Sheath
Taping
Shrink Tubing
Shield
Crimp-on Lug
FV1.25-3 (LF)
Shield
TB2
J2
J1
02P6348
TB1
Red
White
Green
Black
Blue
Green
Black
Cover unused
cable entrance
Cover unused
cable entrance
Detach the grommet;
attach the cord lock
Detach the grommet;
attach the cord lock
Jumper block setting
J2: No output reduction (default)
J1: Output reduction
Connect 10P
connector to
XDR port on
rear of
display unit.
Connect 10P
connector to
XDR port on
rear of
display unit.
Содержание SMD7
Страница 35: ...SMD7 Muiti Function Display OUTLINE DRAWING Tabletop mount REF No C4498 G01 A D 1...
Страница 36: ...SMD7 Muiti Function Display OUTLINE DRAWING Flushmount REF No C4498 G02 A D 2...
Страница 37: ...SMD9 Muiti Function Display OUTLINE DRAWING Tabletop mount REF No C4499 G01 A D 3...
Страница 38: ...SMD9 Muiti Function Display OUTLINE DRAWING Flushmount REF No C4499 G02 C D 4...
Страница 40: ......
Страница 41: ......