6-8 ELECTRICAL SYSTEM
STATOR COIL RESISTANCE
• Remove the fuel tank.
• Disconnect the stator coil lead wire coupler
1
.
Measure the resistance between the two lead wires using the
multi circuit tester. If the resistance is not within the specified
value, replace the stator coil with a new one.
Also, check that the generator core is insulated.
$
Stator coil resistance:
Standard: 13 – 22
Ω
Ω
Ω
Ω
(Yellow – Yellow/Red)
∞ Ω
∞ Ω
∞ Ω
∞ Ω
(Yellow – Ground)
%
Tester knob indication: Resistance (
Ω
Ω
Ω
Ω
)
#
09900-25008: Multi circuit tester set