background image

 

21 

APPENDIX A.

 

LIMITED WARRANTY 

 

ƒ

 

Sutter Instrument Company limits the warranty on this instrument to repair and 
replacement of defective components for two years from date of shipment, provided the 
instrument has been operated in accordance with the instructions outlined in this 
manual. 

ƒ

 

Abuse, misuse, or unauthorized repairs will void this warranty. 

ƒ

 

Warranty work will be performed only at the factory. 

ƒ

 

The cost of shipment both ways is paid for by Sutter Instrument during the first three 
months this warranty is in effect, after which the cost is the responsibility of the 
customer. 

ƒ

 

The limited warranty is as stated above and no implied or inferred liability for direct or 
consequential damages is intended. 

ƒ

 

An extended warranty for up to three additional years can be purchased at the time of 
ordering, or until the original warranty expires. For pricing and other information, please 
contact Sutter Instrument. 

 

LAMBDA HPX HIGH-POWER LED LIGHT SOURCE SYSTEM OPERATION MANUAL – REV. 1.03E  (20141208) 

Содержание Lambda HPX

Страница 1: ...bda HPX High Power LED Light Source System Liquid Cooled Operation Manual Rev 1 03e 20141208 One Digital Drive Novato CA 94949 Voice 415 883 0128 Web www sutter com Fax 415 883 0572 Email info sutter...

Страница 2: ...LAMBDA HPX HIGH POWER LED LIGHT SOURCE SYSTEM OPERATION MANUAL REV 1 03E 20141208 2 Copyright 2014 Sutter Instrument Company All Rights Reserved...

Страница 3: ......

Страница 4: ......

Страница 5: ...trical noise and mechanical vibration Surge suppression is recommended at all times Fuse Replacement Replace only with the same type and rating 2 Amp 250V 5 x 20mm Time Delay fuse EIC 60127 2 Example...

Страница 6: ...E HPX AND THE HIGH POWER LED ASSEMBLY WHILE POWER IS ON Operate this instrument only according to the instructions included in this manual Do not operate if there is any obvious damage to any part of...

Страница 7: ...p can cause significant skin burns and eye damage Avoiding Physical Injury and Equipment Damage while Using High Power LED WARNING Before removing the High Power LED Assembly from the HPX controller m...

Страница 8: ...6 This page intentionally left blank LAMBDA HPX HIGH POWER LED LIGHT SOURCE SYSTEM OPERATION MANUAL REV 1 03E 20141208...

Страница 9: ...ontrol by TTL IN Switch 2 13 2 3 3 LED On Off State while Transitioning Between LED Switch Positions ON and TTL Switch 3 13 2 3 4 Firmware and Lambda HPX Model Switch 4 13 3 OPERATIONS 15 3 1 Indicato...

Страница 10: ...TECHNICAL SPECIFICATIONS 25 APPENDIX D COOLANT FLUID SAFETY DATA SHEET 27 INDEX 33 TABLE OF FIGURES Figure 1 1 HPX indicators controls and connectors 9 Figure 2 1 Lambda HPX series left side panel re...

Страница 11: ...controls and connectors The Lambda HPX is a liquid cooled high output LED light source illuminator Designed around a single 90W 4 25mm LED die the Lambda HPX provides light output comparable to a 200...

Страница 12: ...ery fast on and off open and close times of 5 and 2 5 microseconds respectively TTL input and output allows for software triggering In addition to manual control on the front panel external PWM contro...

Страница 13: ...the High Power LED assembly into the High Power LED Connector on the front panel of the HPX Position the top of the connector slightly to the left gently push inwards toward the connector and then twi...

Страница 14: ...ugh 4 left to right The definitions of these switches and their positions are described in the following paragraphs and are summarized in the table that follows 2 3 1 TTL IN to TTL OUT Logic Switch 1...

Страница 15: ...djustable and TTL modes from the LED switch s ON or OFF position to TTL When ON default lamp turns on When OFF lamp turns off After switching from manual control to TTL TTL control of the lamp s on of...

Страница 16: ...Lamp state when switching from manual control to TTL OFF Lamp turns off Note 1 ON Lambda HPX L5 4 Lambda HPX model specific operation Note 3 OFF Lambda HPX Default NOTE 1 After switching from manual m...

Страница 17: ...in terms of amperes Intensity 5 Current 18 AMPS Figure 3 2 Status display Intensity ranges from 0 to 100 Current ranges from 4 to 18 Amps 3 1 2 Coolant Level Indicator This indicator is a liquid leve...

Страница 18: ...sity PWM Knob This knob dims the LED via Pulse Width Modulation In essence the LED is being switched at 30KHz This is the preferable mode of dimming for most applications as the LED will run cooler an...

Страница 19: ...liquid cooling disconnected may burn out the LED 3 3 3 ANALOG IN BNC Connector An analog input from 0 5v controls intensity through PWM dimming 3 3 4 TTL IN BNC Connector Allows for the control of th...

Страница 20: ...LAMBDA HPX HIGH POWER LED LIGHT SOURCE SYSTEM OPERATION MANUAL REV 1 03E 20141208 18 This page intentionally blank...

Страница 21: ...t all cables ensuring that all connections are made well and connectors are evenly seated 4 2 Liquid Coolant Replacement If the level of liquid coolant runs low additional coolant can be poured into t...

Страница 22: ...LAMBDA HPX HIGH POWER LED LIGHT SOURCE SYSTEM OPERATION MANUAL REV 1 03E 20141208 20 This page intentionally blank...

Страница 23: ...tory The cost of shipment both ways is paid for by Sutter Instrument during the first three months this warranty is in effect after which the cost is the responsibility of the customer The limited war...

Страница 24: ...LAMBDA HPX HIGH POWER LED LIGHT SOURCE SYSTEM OPERATION MANUAL REV 1 03E 20141208 22 This page intentionally blank...

Страница 25: ...ed LED housing adaptors for various microscopes are available Please contact Sutter Instrument for more information 4 6 TTL Triggering A USB controlled trigger box is available for TTL control of the...

Страница 26: ...LAMBDA HPX HIGH POWER LED LIGHT SOURCE SYSTEM OPERATION MANUAL REV 1 03E 20141208 24 This page intentionally blank...

Страница 27: ...TL or analog for input TTL for output Dimming PWM or Current Control LED Wavelength Cool white Tungsten white Options 623 525 460 405 and 385 nm Electrical Input Mains 100 240 VAC 50 60 Hz Output 3 3...

Страница 28: ...LAMBDA HPX HIGH POWER LED LIGHT SOURCE SYSTEM OPERATION MANUAL REV 1 03E 20141208 26 This page intentionally blank...

Страница 29: ...n Globally Harmonized System of Classification and Labeling of Chemicals GHS Physical Hazard Not applicable Health Hazard Skin Irritation Category 2 Eye Irritation Category 2 Environmental Hazard Not...

Страница 30: ...nutes If irritation remains consult a medical doctor immediately If inhaled Move person to fresh air If not breathing give artificial respiration and immediately contact emergency medical assistance I...

Страница 31: ...Avoid direct sunlight heat sources and strong oxidizing agents 8 Exposure Control Personal Protection Conditions for safe storage KOSHA No data available US ACGIH No data available Appropriate engine...

Страница 32: ...Category 2 Eye irritation Irritating Calculated Category 2 Respiratory sensitization No data available Skin sensitization No data available Germ cell mutagenicity No data available Carcinogenicity No...

Страница 33: ...a toxic chemical Korea Persistent Organic Pollutants Control Act Not applicable US OSHA Hazards GHS Eye irritation US OSHA Hazards GHS Skin irritation 16 Other Information References GHS Classificati...

Страница 34: ...bility or any other warranty express or implied with respect to such information and we assume no liability resulting from its use Users should make their own investigations to determine the suitabili...

Страница 35: ...ay 15 input analog 27 TTL 27 voltage 27 installation 11 unpacking 11 Installation 11 instructions 11 introduction 9 description 9 features 9 technical support 10 L LED bulb life 27 dimming 27 current...

Страница 36: ...tch 16 precautions 3 electrical 3 PWM frequency 27 S safety data sheet coolant fluid 31 safety warnings 3 electrical 3 safety warnings precautions operational 4 safety warnings precautions 3 4 shutter...

Отзывы: