P Line Maritim HMI
Interfaces of the Device
47
4.6
Shielding D-SUB Connectors
You must shield D-SUB connectors as follows:
Figure 4-10 Shielding D-SUB connectors
1
D-SUB connector
2
Shield
3
Cable clip
4
Cable
The shield must be folded back into a flat position over the cable sheath.
When fastening the cable with the cable clip, as much of the shielding as possible
must be in contact with the housing and sufficient strain relieve must be ensured.