background image

Содержание ModbusLink-M

Страница 1: ...ModbusLink M ModbusLink S OPERATIONS MAINTENANCE MANUAL Part No 8800 1197 Revision 1 0 April 1 2013...

Страница 2: ......

Страница 3: ...on 6 Modbus Connections 6 ModbusLink Network basics 6 Setup 8 Configuring ModbusLink 9 Optional Mounting Bracket Kit 2911 1395 10 Quick Start Guide 12 Verifying Communication 12 6 Troubleshooting and...

Страница 4: ...ensor directly it will try to discover a route to the destination via intermediate ModbusLink S modules Features 300 meters LOS range longer ranges possible via intermediate nodes mesh networking Very...

Страница 5: ...tainer and visually inspect the unit for signs of damage during shipment Report any such damage to the factory immediately to ensure a prompt response and resolution Retain one shipping container in t...

Страница 6: ...ogger sensor over RS 485 a 5 terminal connector is provided The module can also be provided external power via the 5 pin connector Please refer to Table 1 for a detailed description of the connector T...

Страница 7: ...dbus over RS485 B Red 8 16v dc power input Black Power Ground Battery Connections The ModbusLink M S has an internal battery to power the unit however external power 8 16v dc can be applied to J3 If e...

Страница 8: ...se of simplicity the Network ID can be represented by an imaginary physical wire connecting each ModbusLink module to other ModbusLink modules within radio range having an identical Network ID in a me...

Страница 9: ...te Once a route has been established data can be sent through the route to the destination node Data messages are never broadcast to conserve power They are only addressed to a single node unicast whi...

Страница 10: ...is connected to the ModbusLink S at power up Also ensure that the modbus communication parameters like baud parity etc of the sensor are the same as ModbusLink S module If the parameters are differen...

Страница 11: ...lue CR LF Command value Response Description AT OK Test RS232 communication with module Modbus Com value value RS232 RS485 Modbus Com value Where value the new modbus com port Set Modbus communication...

Страница 12: ...s returns the address and hop count for each node Performs a live Scan and report the address and hop count for all nodes in the current network ver NW Stack Ver x xx Modbus Stack Ver x xx Returns the...

Страница 13: ...1 The optional mounting bracket kit provides an easy way to mount the ModbusLink modules to a 1 5 standard pipe The kit includes the mounting plates alignment bracket and u bolts hose clamps and screw...

Страница 14: ...arity types To change the Network ID issue command NwID Network Id Power cycle the device Node Address config The ModbusLink S modules can be configured to operate in 2 address modes 1 Static address...

Страница 15: ...of the Modbus sensor If using automatic address mode ensure that the Modbus sensor is powered and connected to the ModbusLink S module before powering it up Power cycle the ModbusLink S module Ensure...

Страница 16: ...aud Rates 4800 9600 19200 38400 57600 Parity Odd Even None Mechanical Environmental Enclosure 5 x 4 x 2 NEMA rated enclosure Weight 400gms including battery Temperature 40C to 60C Power Input optional...

Страница 17: ...th our Integrated Systems Division and Engineering Division for additional assistance Introductory Training Training is an important part of the Sutron Customer Service philosophy The Sutron training...

Страница 18: ...shall pay transportation for the return of the repaired equipment to the customer when the validity of the damage claim has been established Otherwise Sutron will prepay shipment and bill the custome...

Отзывы: