background image

Sutron Corporation   8310 & 7310 Users Manual  

8800-1125Rev. 2.7 (BETA)   

12/23/2014  

 

    pg. 

6

 

 
 

 

Recommended Jumper Settings 

 
 

JUMPER 

JUMPER 
POSITION 

Function 

FACTORY 

DEFAULTS 

XPERT 

XLITE 

SDR 

Bubbler 

8210 

 

 

 

 

 

 

 

 

J5 DSR 

1-2 

DSR=CD 

 

 

 

2-3 

DSR=DSR 
(normal) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J4  Wake-
up

 

1-2 

Wake on RTS 

 

 

 

2-3 

Wake on DTR 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J3  Pin  9 
use 

1-2 

RI out 

 

 

 

 

 

 

2-3 

Power in 

 

Note: Sutron’s products do not require the RI signal and J3 should be left in the factory default position of 2-3.  
If using the modem with a device/software that requires RI to announce an incoming call, change J3 to position 
1-2.  

*For the modem to go to a full sleep, the jumper J4 must be removed (or turned sideways on one of the 

pins) when using with an SDR.  This means the SDR will not be able to wake the modem, but since the SDR 
does not have the ability to dial out, is not an issue. 

Содержание 8080-0005-1B

Страница 1: ...8080 0005 VOICE MODEM Operations Maintenance Manual Covers 8080 0005 1B and 2B Part No 8800 1178 Rev B November 17 2014...

Страница 2: ...UNDING 5 RECOMMENDED JUMPER SETTINGS 6 OPERATION WITH THE XPERT XLITE 7 OPERATION WITH XPERT NIFC OPTION 2 MODEL 9 CONNECTION TO BK RADIO 9 OPERATION WITH A PC 10 OPERATION WITH SUTRON SENSORS AND LOG...

Страница 3: ...th some special power saving features These features include RS232 interface baud rate up to 115 200 V 34 33 6 kbps data sending and receiving Voice playback and record DTMF decode 40o C to 60o C exte...

Страница 4: ...ctly to DTE devices such as the Xpert and XLite or a PC using a straight cable Jumpers allow the DTE device to provide power to the modem through pin 9 of the DB9 connector For connection to devices t...

Страница 5: ...ground Pin 5 of the DB 9 Supply voltage 5 to 16 VDC Power can either be supplied via this terminal or via pin 9 of the DB 9 connector If power is supplied from both modem will pull power from the hig...

Страница 6: ...ut 2 3 Power in X X X X X Note Sutron s products do not require the RI signal and J3 should be left in the factory default position of 2 3 If using the modem with a device software that requires RI to...

Страница 7: ...dem This is done by adding or editing the line where the remote program is run Note you create or edit the file on your PC and then use XTERM to transfer the file to the Xpert Adding the text voice3 1...

Страница 8: ...ICE is selected for COM3 a plus sign will allow the VOICE3 to be configured Set answer mode number of rings and language Set phone number s number of redials and the redial delay for alarms For voice...

Страница 9: ...speech playback capabilities for the Xpert Station With this option the modem DOES NOT operate as a normal phone line modem and SHOULD NOT be connected to a phone line The validation of the Station I...

Страница 10: ...ct No Connect 3 Red Ring 3 ground Ground reference 4 Green Tip Ext Speaker signal Audio into modem 5 Yellow R2 4 mic audio Audio out of modem 6 Operation with a PC Connect modem to external power 5 to...

Страница 11: ...E0 don t echo characters Q1 don t send result codes D0 ignore DTR W save settings into profile A null modem cable is needed between the device and the modem since they are both configured as DCE devi...

Страница 12: ...S In this mode the power is turned off to the modem thus conserving the 360 mW that the modem would otherwise use When a ring is detected on the phone line the power is automatically turned on to the...

Страница 13: ...Xpert com1 issue the command type autoexec bat Verify that remote exe is being set for a modem connection on the correct com port I E a line that states windows remote exe com1 115200 voice3 115200 Ma...

Страница 14: ...ng in response to an incoming call In most but not all areas the sum of the REN should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the t...

Страница 15: ...owered over RS 232 cable Wide input power supply of 5 to 16V Digital Line Guard for protection if accidentally connected to digital telephone line Built in transient protection Agency Approvals 8080 0...

Страница 16: ...Sutron Corporation 8310 7310 Users Manual 8800 1125Rev 2 7 BETA 12 23 2014 pg 16 Power Consumption 500 mW Transmit Receive Level 10 Tx 43 Rx dbm...

Страница 17: ...untry code is changed you do not have to store the setting with the AT W command The modem will automatically store the setting when the AT GCI command is issued It will remain in effect until overwri...