10 Sensor signal outputs
If the flow rate is too high, the S421 cannot output the pulses with
default settings (one pulse per consumption unit). In this case, you
can set the pulse to 1 pulse per 10 consumption units or 1 pulse per
100 consumption units, using the S4C-FS service App (S4C-FS) or a
connected display.
Example: with setting of 1 pulse per 10 m
3
, the sensor sends one pulse
each 10 m
3
.
Volumetric
flow
[m
3
/s]
Volumetric
flow
[m
3
/h]
Pulse length
[ms]
Max. pulse
output
per hour
≦
3
≦
10800
120
1080
> 3
> 10800
60
2880
> 6
> 21600
30
3960