10 Sensor signal outputs
10 Sensor signal outputs
10.1 Analog output
The sensor can provide an analog output of 4 ... 20 mA. This output can
be scaled to match the desired measuring range. The standard scaling is
from 0 to max flow.
The corresponding flow rates to different pipe sizes can be calculated
using the free "Flow range calculator" tool available in
http://www.suto-itec.com
. For more information about how to
on page 10.
For other ranges, please contact the manufacturer.
10.2 Pulse output
The sensor outputs one pulse per a consumption unit. This pulse output
can be connected to an external pulse counter to count the total
consumption. The number of m
3
per second is summed up and indicated
after one second. Pulse length depends on flow rate.