5 Technical data
5
Technical data
5.1 General
FCC ID:
2ASK2-SUTO-001
Parameters
Standard unit flow: m
3
/h
Other units: m
3
/min, l/min, l/s, cfm, kg/h,
kg/min, kg/s
Consumption units: m
3
, ft
3
, kg
Reference conditions
ISO1217 20°C 1000 mbar (Standard-Unit)
DIN1343 0°C 1013.25 mbar (Norm-Unit)
Principle of
measurement
Thermal mass flow
Sensor
Glass coated resistive sensor
Measuring medium
Air, gas (non corrosive gas)
Operating temperature -30 ... +140°C fluid temperature
-30 ... +70°C casing
-10 ... +50°C display (optional)
Humidity of the meas.
medium
< 90%, no condensation
Operating pressure
Up to 5.0 MPa (> 1.6 MPa needs the installation
device)
Housing material
PC + ABS
Material of the probe
tube, sensor head
(wetted parts)
Stainless steel 1.4404 (SUS 316L)
Protection class
IP65
Dimensions
See dimensional drawing on the next page
Display (optional)
2.4” color graphics display with keypad
Tube diameter
1/2” to 12” (bigger diameters on request)
Process connection
G1/2” (ISO 228/1)
Weight
0.9 kg (220 mm standard)
0.85 kg (160 mm), 0.95 kg (300 mm),
1.0 kg (400 mm)
9