background image

  

 

 

SUSPA GmbH 

 

Assembly Instructions 

 

 

 

English 

 

 

 

 

Table Frame 
Type VariFrame 

 

 

 

 

 

 

 

The  assembly  instructions  must  be  read  carefully  prior  to  initial 
commissioning! 
Follow the safety instructions! 
This  table  frame  is  intended  to  be  incorporated  into  machinery,  partly 
completed machinery/equipment or to be joined with another framework 
so  as  to  form  a  complete  machine  as  specified  under  the  Machinery 
Directive. The machine should be put into operation only after a conformity 
evaluation procedure in accordance with the Machinery Directive has been 
carried out for the complete machine. 
 
No revision service applies to this documentation. The updated assembly 
instructions are available at  

http://www.suspa.com/de/service/downloads/

  

Содержание VariFrame

Страница 1: ...ted machinery equipment or to be joined with another framework so as to form a complete machine as specified under the Machinery Directive The machine should be put into operation only after a conform...

Страница 2: ...est doubt arises The manufacturer is not liable for injuries to people or animals and damage to objects or to the machine itself arising from the improper unauthorized use or by ignoring the safety cr...

Страница 3: ...nction of the table frame 14 4 2 1 Packaging units and weights 16 5 Installation 17 5 1 Unpacking 17 5 1 1 Disposal of transport and warehouse packaging 17 5 1 2 Checklist of all components included i...

Страница 4: ...Laying of electric wires and cables exemplary 33 5 4 Space requirements 33 5 5 Setting up and aligning the table 34 6 Service and maintenance 35 6 1 General 35 6 2 Maintenance instructions 35 6 2 1 Cl...

Страница 5: ...s and signal colors The following signal words are based on DIN EN 82079 1 and ANSI Z 535 4 and are used in this documentation The safety colors have been taken from standard ISO 3864 1 Signal word Us...

Страница 6: ...xt of these assembly instructions and require special attention depending on the combination of signal word and symbol Symbol Use Explanation Note Important information for understanding the device or...

Страница 7: ...bled table base frame is joined with the tabletop The system is only designed for load that applies pressure IMPORTANT Prior to installation or commissioning ensure that the appropriate table frame ha...

Страница 8: ...and maintenance of the system operating the table frame beyond the physical operating limits described in section Operating conditions any modifications to the table frame as well as any add ons or co...

Страница 9: ...he details associated with function and maintenance The assembly instructions must be made accessible to personnel at all times and must be kept available near the table frame Read and observe the inf...

Страница 10: ...ersons who can evaluate the work assigned to them and recognize possible dangers on the basis of their specialized training knowledge experience and familiarity with the relevant standards External sp...

Страница 11: ...third parties or to the components use the components only for intended purpose and in perfect operating condition in terms of safety The operator of the components or the persons assigned by the same...

Страница 12: ...onformity evaluation procedure in accordance with the Machinery Directive has been carried out for the complete machine 3 2 Additional instructions Basically the provisions of the accident prevention...

Страница 13: ...s to be attached to ELS3 lifting column pos C Length 750 mm Width 90 mm Height 20 mm Hole pattern Round section circle 45 mm borehole 9 mm Foot base RE dimensions to be attached to ELS3 lifting column...

Страница 14: ...tching tabletop forms an electrically height adjustable workbench The table frame mainly consists of four components Cross beam Fixing plate Foot base Installation kit The individual components and th...

Страница 15: ...ction VariFrame Assembly Instructions page 15 Figure 3 Fixing plate length 545 mm pos B Figure 4 Foot base Q length 750 mm pos C Figure 5 Foot base RE length 750 mm pos D Figure 6 M6 x 10 mm raised he...

Страница 16: ...x nut pos F The foot base Q pos C or foot base RE pos D are screwed to the bottom end of the lifting column The tabletop is screwed together with the cross beams pos A and the fixing plates pos B 4 2...

Страница 17: ...g the system components Do not use any sharp edged objects cutters or knife blades in order to prevent damage to components that may get damaged easily Check the delivery for completeness damage or an...

Страница 18: ...site Office Operating range Functional operation Minimum 15 C Maximum 30 C Relative humidity 60 maximum Contamination No heavy contamination due to dust acids corrosive gases Table 6 Operating conditi...

Страница 19: ...es and moving parts Avoid contact with moisture and heat Attach the electrical wires and power cords to the workstation or structure using cable ties or clips IMPORTANT When laying cables make sure th...

Страница 20: ...e figure 10 The tabletop should not protrude more than 100mm on the longitudinal side over the table base frame see figure 10 The tabletop should not protrude more than 130 mm on the narrow side over...

Страница 21: ...very for the table frame from the packaging Place the tabletop not included in the scope of delivery with its top surface down onto a stable surface Protect the top surface of the tabletop against scr...

Страница 22: ...letop size 1200 mm x 800 mm Place one cross beam each pos A to the right and left of the lifting columns The lifting columns and cross beams must be aligned with each other The boreholes for the cross...

Страница 23: ...ight and left of the lifting columns The lifting columns and cross beams must be aligned with each other The boreholes for the cross beam match the boreholes for the lifting columns The cross beams sh...

Страница 24: ...ace a fixing plate each pos B in a way as to allow the clip of the fixing plate pos B to clasp around the cross beams pos A and the lifting column The elongated holes in the fixing plate match the bor...

Страница 25: ...e pos B 6 x pos E M6x10 raised head screw Before finally tightening the raised head screws to fasten the cross beam and the fixing plate to the lifting columns properly align the components with each...

Страница 26: ...tive torque on the longitudinal sides of the motor housing If multiple bore holes are provided additional screws may be added IMPORTANT Screws to fasten the lifting columns to the frame are not includ...

Страница 27: ...to the tabletop using 24 chipboard screws or similar Figure 18 Screw connection of the table base frame WARNING A risk of sustaining injuries due to protruding screws is posed ATTENTION Use screws wit...

Страница 28: ...countersunk bolts pos G Max tightening torque for pos G M8 screw is 10Nm Retighten the screws crosswise to fasten the foot base to ensure they are well anchored Ensure that the foot base are aligned p...

Страница 29: ...d screws to attach the foot base pos G The functionality of the lift is only guaranteed when the supplied screws are used Observe the maximum torque of 10 Nm for the screws pos G The foot base must ea...

Страница 30: ...included in the scope of delivery can be plugged into the controller Fasten the controller to the boreholes provided on the bottom of the tabletop between the two cross beams 2 fastening points Figur...

Страница 31: ...n of the manual switch ATTENTION Use screws with the proper length only Screws that are too long will penetrate the top surface of the tabletop and damage it WARNING A risk of sustaining injuries due...

Страница 32: ...ct the plug of the manual switch to the electrical controller using the appropriate input Plug the connectors of the lifting columns into the electrical controller Plug the power connector into the ma...

Страница 33: ...way Fasten the lines with adequate strain relief and adequate protection against kinks Wind up long electrical lines and attach them with adequate cable holders not included in the scope of delivery o...

Страница 34: ...base At least two people are needed to place the fully assembled table on its feet If necessary level the table using the adjustable glides Reset the system see https suspa com suspa downloads and ht...

Страница 35: ...loosened after doing maintenance and service work Reattach disassembled protective devices before the first re commissioning Make sure that the protective equipment is functioning properly Perform a f...

Страница 36: ...may be carried over during operation leading to so called run marks on visible pipe surfaces These may be wiped off with mild cleaning agent and a cloth Before restarting operation make sure the syst...

Страница 37: ...s and preserving agents separately and professionally The users are obliged to return the old equipment to a recycling center for old electrical and electronic equipment The disposal of the controller...

Страница 38: ...Appendix 8 1 Index of Tables Table 1 Signal words and signal colors 5 Table 2 Symbols 6 Table 3 Warning notice 6 Table 4 Target group 10 Table 5 Technical specifications 13 Table 6 Operating conditio...

Страница 39: ...ith the tabletop 20 Figure 11 Positioning the lifting columns 21 Figure 12 Positioning the cross beam pos A 22 Figure 13 Positioning the cross beam pos A 23 Figure 14 Positioning of the fixing plates...

Отзывы: