Surround Air XJ-3800 Скачать руководство пользователя страница 2

l

Plug Type: US 120V (120VAC/60HZ)

l

Power: 80W

l

HEPA Cleaning Efficiency: 99.97%

l

Dimensions: 24 x 13.5 x 10 (in)

l

Weight: 15 lbs.

l

Maximum Air Volume: 106 cfm

l

UV wavelength: 254 nm (germicidal wavelength)

l

Odor and dust sensors for automatic air quality control.

l

Sensors indicate when to replace filters and clean collector grid.

l

UV light and negative ion indicator sensors.

l

Long-lasting, high-efficiency HEPA filter - 99.97% collection rate.

l

Electrostatically-charged plasma cell traps pollutants like a magnet.

l

Activated Carbon Filter to adsorb chemicals, cigarette smoke and odors.

l

Photocatalytic Filter (TiO2) to remove airborne chemicals, odors and bacteria.

l

Germicidal UV (Ultraviolet) Lamp to destroy micro-organisms.

l

Negative Ion Generator to circulate air-cleaning negative ions throughout the room.

l

Washable pre-filter to collect larger particles and to prolong the life of the other filters.

l

Powerful yet quiet fan for maximum air circulation.

1. To prevent electric shock, do not dismantle, repair or modify this product beyond the instructions given
in this manual. In case of malfunction, please contact Surround Air.
2. Do not use in places where flammable and explosive materials are stored.
3. Do not allow foreign objects into this device. High voltage inside the device may cause electric shock.
4. To avoid interference, this device should be placed at least 3 feet away from computers, televisions or
radios.
5. Do not cover this device with fabrics or any other materials.
6. Do not use in places where flammable and explosive materials are stored. Do not subject to sunlight or
high-temperature objects. Significant rises in internal temperature may cause fire or deformation of the
outer shell. Stop operation when temperature exceeds 104

o

F.

6. Do not block the air inlet or outlet.
7. Do not move the device while it is in operation.
8. Make sure that all filters are in place before operating.
9. To prevent short-circuit or electric shock hazard, do not place the device in places that are wet or
where water may potentially enter the unit.
10. Before unplugging the device, turn the power off, along with all control functions.
11. Do not operate if the power cord is damaged.
12. To prevent fire or electric shock, unplug the machine from the electrical outlet under the following
conditions: when it is not operated for long periods, while cleaning or replacing filters or UV bulbs, or
when the machine is being moved.

Specifications

Functions

Cautions

Содержание XJ-3800

Страница 1: ...ual Please read before using air purifier Surround Air Division Indoor Purification Systems Inc 334 Marshall Way Suite C Layton Utah 84041 Toll Free 888 812 1516 PH 801 444 0606 FX 801 991 4838 Web ww...

Страница 2: ...2 Do not use in places where flammable and explosive materials are stored 3 Do not allow foreign objects into this device High voltage inside the device may cause electric shock 4 To avoid interferen...

Страница 3: ...Diagram External Control Panel Control Panel Control Panel Control Panel Control Panel...

Страница 4: ...Diagram Internal...

Страница 5: ...and sensitive electrical equipment and two feet from occupants in the room while in operation l To the extent possible it is optimal to place the Intelli Pro in areas 1 nearest the source of airborne...

Страница 6: ...utton and the UV Negative Ion Indicator will be lit Press POWER ON OFF again and the device will stop working Fan Modes This device has five different fan modes to choose from Please choose a proper l...

Страница 7: ...is recommended to perform cleaning and maintenance at least every 2 to 3 months Disassembling the Air Purifier Carefully lay down the device with its front facing up take down the device according to...

Страница 8: ...Cleaning and Maintenance...

Страница 9: ...dirt presoak with diluted detergent and then use a toothbrush to scrub l Please beware not to damage any wiring while cleaning the dust collector l If any electrical discharge wire is broken the devi...

Страница 10: ...ilters reset the CLEAN METAL GRID and REPLACE FILTER indicators Otherwise the two indicators would remaining glowing after turning the unit back on While resetting the unit should remain plugged into...

Страница 11: ...inAuto operation Cleaning Steps 1 Remove the front cover along with the dust sensor cover 2 Remove the dust sensor and carefully unplug its connecting cord Make note of how it is plugged in 3 Unscrew...

Страница 12: ...ll phones and other wireless equipment away from the unit Dust and Pollutant Sensor Q Why does the Dust and Pollutant Sensor keep blinking A The top of the sensor has accumulated too much dust and nee...

Страница 13: ...vent shall the manufacturer be liable for special incidental consequential or indirect damages This warranty does not cover a defect that resulted from improper or unreasonable use or maintenance acci...

Страница 14: ...und Air Division Indoor Purification Systems Inc 334 Marshall Way Suite C Layton Utah 84041 Toll Free 888 812 1516 PH 801 444 0606 FX 801 991 4838 Web www surroundair com Email support team surroundai...