User Manual

 

 

 

© 2017 AMETEK Electronic Systems Protection   /   Technical Support: 1-800-645-9721   /   surgex.com                                    12 

 

 

 

ii.  Real-time display of electrical parameters 

 

• 

Line Voltage: AC RMS Volts. Peak Measurement Type 

• 

Neutral-Ground Voltage: AC RMS Volts Neutral-Ground. Peak 
Measurement Type. Available with 120V models with firmware 
version 2.00 and later. ±1V accuracy from 3V-10V. 

 

iii.   Number of recorded power quality events 

 

• 

Surge Events: SG 

• 

Overvoltage Events: OVrec 

• 

Undervoltage Events: UVrec 

• 

Power Outage Events: PO 

 

b.    Chart Mode 

 

i. 

The Chart Mode enables a chart style data logging function of electrical 
parameters. Data point measurements are acquired once per second. 
The measured parameters may be enabled or disabled by pressing the 
corresponding button. 

 

 

 

 

 

ii.  Chart display of electrical parameters: 

 

• 

Line Voltage: AC RMS Volts. Peak Measurement Type 

• 

Neutral-Ground Voltage: AC RMS Volts Neutral-Ground. Peak 
Measurement Type. Available with 120V models with firmware 
version 2.00 and later. ±1V accuracy from 3V-10V.

Содержание SX-DS-154 DEFENDER SERIES MULTIPAK

Страница 1: ...l 2017 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com UM MultiPak Rev B 0 SX DS 154 SX DS 156 User Manual 120V Firmware Revision 1 67 and higher Software Revision 4 0 and higher ...

Страница 2: ...UserManual 2017 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com 1 ...

Страница 3: ...5 IV SOFTWARE INSTALLATION 6 1 COMPUTER REQUIREMENTS 6 2 HARDWARE REQUIREMENTS 6 3 DOWNLOAD AND INSTALL SOFTWARE 6 4 INSTALL DATA INTERFACE CABLE 7 V USING THE SOFWARE 7 1 PHYSICAL CONNECTIONS 7 2 START THE SOFTWARE 7 3 CONFIGURE THE DATA INTERFACE CABLE AND COM PORT 8 4 SOFTWARE MODES 10 A MULTIMETER MODE 11 B CHART MODE 12 C OUTLET CONTROL MODE 13 D HISTORICAL DATA MODE 14 E SETTINGS MODE 16 F C...

Страница 4: ...resholds Under Voltage Event Recorder up to 999 events Over Voltage Event Recorder up to 999 events Power Outage Event Recorder up to 999 events Surge Event Recorder up to 999 events o Records surges in all three modes Line Neutral Line Ground Neutral Ground Event Timestamp Recorder up to 60 events o Records time between events Additional features available when connected to a PC detailed in Secti...

Страница 5: ...orrectly wired and the magnitude of the line voltage is acceptable between 105 and 130 VRMS power will be connected to the outlets of the MULTIPAK and the Green System On LED will illuminate Your equipment is now protected and installed correctly You may now turn all connected equipment back on ii If the branch circuit outlet is incorrectly wired the Red Wiring Fault LED will illuminate If this oc...

Страница 6: ...When the magnitude of the branch circuit outlet voltage is not acceptable the MULTIPAK will disconnect power to its outlets refer to Section IV Diagnostic Software for more information d Clearing Memory The MULTIPAK is able to timestamp the 60 most recent power quality events information stored in microcontroller non volatile memory The microcontroller memory contents can be cleared at any time by...

Страница 7: ...pace VGA or higher resolution monitor keyboard mouse CD or DVD drive minimum screen resolution of 1024x768 Microsoft Windows XP Vista 7 8 10 2 Hardware Requirements a For use with enVision enabled products and Data Interface Cable XG PCS 1C 1 3 Download and Install Software a Download the Software Installer from www espsurgex com b Unzip and run the installation utility c Follow the on screen inst...

Страница 8: ...erial Port drivers separately b Manual Installation In the event that the automatic driver installation process was not successful or if no internet connection is available the Data Interface Cable driver files may be installed manually Select Install Drivers during the Software Installation process Or run Interface Setup from Start All Programs ESP SurgeX Diagnostic Tool c Once the Data Interface...

Страница 9: ...ftware and Next Gen Note This process only needs to be done once for each new Data Interface Cable installed on the PC Note This process edits Windows registry values and so may be blocked by MS Windows User Account Control UAC in Windows Vista 7 8 10 It may be necessary to exit the software and restart it with administrative rights by right clicking the software shortcut and choosing Run As Admin...

Страница 10: ...and in the Search box devmgmt msc c Press Enter 2 In the Device Manager expand Ports COM LPT 3 Right click on the entry labeled USB Serial Port COMx and click Properties 4 In the USB Serial Port Properties pop up box click the Port Settings tab and then click the Advanced button 5 In USB Transfer Sizes change both the Receive and Transmit values to 4096 6 In BM Options change the Latency Timer val...

Страница 11: ...nto several operational modes The modes are activated by clicking the corresponding button at the bottom of the software interface Note Some features are only available when used with an enVision PCS product Press the Help Button in the upper right for additional information on the features available in the current mode Hovering the mouse cursor over items will also display additional information ...

Страница 12: ...echnical Support 1 800 645 9721 surgex com 11 a Multimeter Mode i The Multimeter Mode provides information traditionally acquired from a handheld digital multimeter as well as an overview of the recorded power quality events 2 Typical Measurement Accuracy ...

Страница 13: ...ty events Surge Events SG Overvoltage Events OVrec Undervoltage Events UVrec Power Outage Events PO b Chart Mode i The Chart Mode enables a chart style data logging function of electrical parameters Data point measurements are acquired once per second The measured parameters may be enabled or disabled by pressing the corresponding button ii Chart display of electrical parameters Line Voltage AC RM...

Страница 14: ...nd provides information about wiring faults and abnormal line voltage ii Use the green On Off button to manually turn the AC outlets on and off Pressing the blue Power Cycle button will result in the execution of a power cycle When commanded the outlets will turn off and then back on after a 90 second delay The Power Cycle indicator will be illuminated while a power cycle is active ...

Страница 15: ...l Data Mode allows for the retrieval and display of the power quality event data stored in the Next Gen internal memory i Time Stamped Power Quality Event Data Next Gen is able to store and timestamp the 60 most recent power quality events in its internal memory Press the Import Time Stamped Data button to download the event data yuikl ...

Страница 16: ...tage amplitudes necessary for detection of other surge types may vary Over Voltage Line voltage exceeded the over voltage record threshold Under Voltage Line voltage dropped below the under voltage record threshold Power Outage Loss of AC power ii Import Data Previously saved data files may be imported by entering the Historical Data Mode while no product is connected This may be achieved by remov...

Страница 17: ...ID for saved reports iii Update Limits Sets the voltage thresholds specified by the voltage threshold selection fields Press Default to select factory default limits Note Restore points may not be specified for Next Gen PCS x Language Select the software s display language xi Save Save the current settings for reference Limit When Activated Action Factory Default 120V 208 240V Over Voltage Shutdow...

Страница 18: ...unning the software with elevated permissions right click program shortcut and choose Run As Administrator on Windows Vista 7 8 10 with UAC User Account Control enabled iv Save Saves the COM Port selection 5 Command Line Operation Usage ESP_SurgeX_Diagnostic_Tool o output_file a t c m Example ESP_SurgeX_Diagnostic_Tool o C Users Robert Desktop log txt a m Option Meaning a Append output file If out...

Страница 19: ...uct Contact SurgeX for product replacement at 1 800 645 9721 2 Software Symptom Error Message Possible Cause What To Do Unable to automatically determine COM Port Data interface cable not properly connected Check interface cable connections at PC and XG COM Port not successfully configured Windows User Account Control has prevented the software from automatically modifying the COM Port settings in...

Страница 20: ...UserManual 2017 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com 19 VII Specifications ...