SA-82-AR / XF2-AR User Manual
Page 3
II. Installation
Ethernet Connection
The RJ45 connector for 10/100 Ethernet is situated on the rear
panel beside the input power plug. The default IP Address is
192.168.1.254.
AC Power Connections
Connect the device to be powered On and Off to the output
duplex receptacle.
Ensure that the total combined load of all controlled devices does
not exceed 8 Amps.
Connect one end of the supplied power cord to the connector
labeled “AC Input”, and the other end to a properly grounded AC
outlet.
LED Indicators
The green Self-Test LED indicates that the internal surge protection circuitry is fully functional.
The red Outlet On LED indicates that power is being supplied to the two receptacles.
The red System On LED indicates that the Axess system is On. This indicator will turn off if the
AC voltage rises above 145V, and AC power will be removed from the output receptacles in
order to protect connected equipment. When the AC voltage returns to below 135V, power will
automatically be restored to the output receptacles and the System On LED will turn on.