background image

 
 
 
 
 

 

 

 

 
 

 
 
 
 
 
                             
 
 
 
 

AC-FS5 

Operations Manual

FlavorShot by SureShot™ 

D-19-002 Rev B

Содержание AC-FS5 FlavorShot

Страница 1: ...AC FS5 Operations Manual FlavorShot by SureShot D 19 002 Rev B...

Страница 2: ...5 Dispenser 3 2 Loading Tanks 8 3 Button Panel 12 4 Remove Check Valve 21 5 Check Valve input 21 6 Check Valve output 21 7 Wiring Diagram 26 Tables 1 LCD Display 15 The AC FS5 FlavorShot by SureShot...

Страница 3: ...ATE 1 Place cup on catch tray 2 Press buttons for product desired bottom row select flavor middle row select modifier if required top row select size Capacity 5 x 950 ml tanks Weight 45 pounds empty d...

Страница 4: ...2 mls etc The multi functional button panel enables you to dispense the correct amount for each of your cup sizes and your beverage recipes The flavors are stored in sanitary tanks within the dispens...

Страница 5: ...may damage the dispenser To uncrate follow these instructions 1 Position the box with the This Side Up arrow pointing upward 2 Turn the dispenser box on its side 3 Remove the packaging material at th...

Страница 6: ...t Inc before the service technician is dispatched Contact the SureShot Dispensing Systems Technical Assistance Center at 1 888 777 9990 or 1 902 865 9602 for approval The customer is responsible for a...

Страница 7: ...he Power Switch ON The switch is recessed on the lower left side of the dispenser 3 The LCD window will display Wait and then a series of 5 dots will appear This indicates that all 5 tank pumps are op...

Страница 8: ...om plastic tanks stored within the dispenser Flavors may be transferred from original containers into clean sanitized tanks which are loaded into the dispenser The flavor tanks sit in pumps which must...

Страница 9: ...e tank filled Press the Reset button The LCD will display Reset Full or Reset Low Fill Press the Reset button until Reset Full is displayed CAUTION The accuracy of the low level indicator and lockout...

Страница 10: ...on the Flavor button goes out press and hold the Clean button for two seconds Allow the pump system to empty all residual product 4 When the tank and pump are empty press the Clean button again to ca...

Страница 11: ...t Full is displayed If you refill the tank to the Low level a Press the Flavor button for the tank filled b Press the Reset button The LCD will display Reset Full or Reset Low Fill Press the Reset but...

Страница 12: ...spenser The flavor and volume to be dispensed are selected by pressing buttons on the Button Panel on the front door of the dispenser Press buttons as required BUTTON PANEL Fig 3 Button Panel FlavorSh...

Страница 13: ...d hold for 2 seconds Release the Prime button 2 Press Clean button and hold for 2 seconds 3 Press the Flavor button for the flavor you want the Drink Count Data on e g French Vanilla 4 The LCD window...

Страница 14: ...after 750 ml have been dispensed from the tank Note that approximately 200 ml of flavor is left to be dispensed from the tank when the light begins to flash Once the LED begins to flash the tank can b...

Страница 15: ...tra Large indicates size selected Only S M and L are used at this time Refill Tank indicates tank must be filled to the Full line Reset Full indicates tank level is resetting to Full Reset Low Fill in...

Страница 16: ...tion or if the Clean button is selected accidentally the cleaning cycle may be ended by selecting the Clean button a second time After cleaning and before installing flavor tanks apply a small amount...

Страница 17: ...ay in the dishwasher and washing on the pot cycle 4 RINSE After washing rinse the tray well with lukewarm water 5 SANITIZE Sanitize the tray sanitizer using a mild sanitizer such as chlorine at 100 pp...

Страница 18: ...mp system 1 Place a catch container under the product dispensing block to catch any residual flavor from the tank and pump 2 Press the Flavor button for the tank system to be cleaned 3 Before the red...

Страница 19: ...r Press the Flavor button for the tank to be rinsed Before the red light on the Flavor button goes out press and hold the Clean button for 2 seconds Allow the water in the tank and pump system to run...

Страница 20: ...s of the dispenser TUBE MAINTENANCE Check the dispense tubes periodically to ensure they are not blocked cut cracked or disfigured Damaged tubes must be replaced To replace the tube 1 remove the tube...

Страница 21: ...Do not remove the O rings from either side of the valve housing c insert a new check valve in the proper orientation to direct flow with the input end Fig 5 facing the flavor tank and the output end F...

Страница 22: ...kinks and are not pinched off 4 Make sure the dispensing tube block is clean 5 Prime the tank pump See page 9 6 Turn OFF the dispenser wait 10 seconds then turn the dispenser back ON This resets the...

Страница 23: ...o replace inlet check valve a Empty flavor tank by pressing and holding the Clean button for two seconds and allowing the flavor to drain out b Lift flavor tank out c Loosen the plastic check valve re...

Страница 24: ...ube a remove the tube from the barbed fittings at both ends b cut replacement tube to the length of the tube you are replacing c attach tube to the barbed fittings at each end 2 Make sure the flavor d...

Страница 25: ...on button is flashing NOTE The flashing red light is a warning light to indicate that the volume in the flavor tank is getting low and the flavor will need to be refilled soon A solid red warning ligh...

Страница 26: ...ct your problem or if you have other problems please contact the SureShot Dispensing Systems Technical Assistance Center at 1 888 777 9990 or 1 902 865 9602 if you are within the Warranty Period for y...

Страница 27: ...or service performed by its Authorized Service Agencies The use of other than A C Dispensing Equipment Inc Authorized Service Agencies will void this warranty and A C Dispensing Equipment Inc will not...

Страница 28: ...formed at overtime or premium labor rates Should service be required at times which normally involve overtime or premium labor rates the owner shall be charged for the difference between normal servic...

Отзывы: