SureCall | 48346 Milmont Drive, Fremont CA 94538 | 1-888-365-6283 | [email protected]
17
CHAPTER 5: Configuration & Testing
The Force3 PSB has five dipswitches. Below is an image of the dip-switches and the frequency
bands they utilize for attenuation. Next to the image is a general attenuation guide.
DIP Switches
1) PS 700 DL dip wsitches control 700 band downlink
2) PS UL dip wsitches control 700 band and 800 band uplink
3) PS 800 DL dip wsitches control 800 band downlink
4) SMR 900 UL dip wsitches control 900 band uplink
5) SMR 900 UL dip wsitches control 900 band downlink
Switch 1 (1dB) + Switch 2 (2dB) = 3dB attenuation
Switch 1 (1dB) + Switch 2 (2dB) + Switch 3 (4dB) = 7dB attenuation
Switch 1 (1dB) + Switch 2 (2dB) + Switch 3 (4dB) + Switch 4 (8dB) = 15dB attenuation
Switch 1 (1dB) + Switch 2 (2dB) + Switch 3 (4dB) + Switch 4 (8dB) + Switch 5 (16dB) = 31dB attenuation
Switch 1 Switch 2 Switch 3 Switch 4 Switch 5
1dB 2dB 4dB 8dB 16dB
Configuration and Testing