Operation
Do not attempt to "Light" the Heater if the odor of gas present!!
LIGHTING:
Note: This heater is equipped with a Pilot light that allows for safer startups and shutdowns. The pilot
must be lit before Main Burner can be started.
1.Turn Cylinder Valve ON.
2. Open Viewing Hole by sliding
cover to either side.
3. Push Control Knob IN and
rotate to Pilot position.
N o t e : F o r i n i t i a l s t a r t o r
after any cylinder change, hold Control Knob IN
for 2 minutes to purge air from gas lines before
proceeding.
18
BEFORE TURNING GAS SUPPLY ON:
1. Your heater was designed and approved for outdoor use only. DO NOT use it inside a building,
garage, or any other enclosed area.
2. Make sure surrounding areas are free of combustible materials, gasoline, and other flammable
vapors or liquids.
3. Ensure that there is no obstruction to air ventilation.
4. Be sure all gas connections are tight and there are no leaks.
5. Be sure the cylinder cover is clear of debris.
6. Be sure any component removed during assembly or servicing is replaced and fastened prior to
starting.
BEFORE LIGHTING:
1. Heater should be thoroughly inspected before each use, and by a quali
fi
ed service person at least
annually.
2. If relighting a hot heater, always wait at least 5 minutes.
3. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas
should be leak tested. If the hose leaks, it must be replaced prior to operation. Only use the
replacement hose assembly speci
fi
ed by manufacturer.
4. Hold the Pilot Control Knob in and push the piezo
button until the pilot
fl
ame appears.
5. Continue holding the Pilot Control Knob for up to one
(1) minute before releasing. Pilot should remain lit.
6. Release Pilot Control Knob after 60 seconds. Pilot
Light will remain lit. If not return to Step 1.
7. Turn Pilot Control Knob to ON. Main burner will light
immediately. Flame is visible through Viewing Hole. If
not return to Step 1.