GALAXY
SUPREME FIREPLACES
20
CONNECTOR
FLANGE
LINER
CONNECTOR
FLANGE
HOLDER
TEMPORARY
OPENING
(SEE NOTE)
THREADED STUD (3)
PREFABRICATED CHIMNEY
LINER
FIRESTOP
6'' MIN.
2'' MIN.
ENCLOSURE
PREFABRICATED
CHIMNEY
2'' MIN.
6'' MIN.
ENCLOSURE
LINER
TEE
Figure
25
– Connection to a Masonry Chimney
Figure
24
– Fresh Air Adaptor
Figure
26
– Fresh Air Adaptor
with three self- tapping screws #8: make sure the connector flange is already inserted around the liner connector.
12.
Bring the liner down from the top of the masonry chimney and insert the liner connector in the upper end of the
prefabricated chimney.
13.
Align the holes of the connector flange with the threaded studs of the flange holder, and secure the connection with
the wing nuts.
14.
Using refractory cement that is resistant to high temperatures, close up the opening around the prefabricated chimney.
NOTE: It might be necessary to create a small temporary opening in the side of the chimney to facilitate the connection of
the liner to the prefabricated chimney. Close this opening after the installation is completed with refractory materials.
5.
OPTIONS
5.1
Fresh Air Kit
NOTE:
The fresh air kit is an optional component. The fireplace is designed to use a minimum amount of air when it is
operational. When the fireplace is not in use, there is no air from the house escaping to the chimney.
Do not install the fresh air kit unless it is required by the local authority, state authority
or any other authority having jurisdiction on this matter.
Sufficient air exchange is necessary for the fireplace to operate properly. Air is required in
order to maintain the combustion of the fireplace. If the house is airtight, the fireplace may
not function properly. If the fireplace is deprived of air, it will be necessary to provide a source
of fresh air into the dwelling. This may be done by using an air exchanger unit or simply by
opening a window or a door near the fireplace partially for a few minutes. Consult local
authority having jurisdiction (such as the fire department, the municipal building department,
the fire prevention bureau) to determine if it is mandatory to install a fresh air kit in your area.
General notes:
The outside air kit should be installed according to the following guidelines.
The air duct must be insulated and have a 4 inch inside diameter.
The length of the air duct should be as short as possible.
Fresh air must come from the outside and not from another room or the attic.
The outside register must be away from automobile exhaust fumes, gas meters or other vents.
Avoid installing the air register where it will likely be covered by snow or exposed to strong winds.
The air register could be installed above or below the level where the fireplace is installed.
Use the Supreme Fresh Air Kit (part #
UPEA4
) or any other fresh air kit with the same specifications and intended for
fireplace use.
Installation: